Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: ELDORADO NATIONAL - KANSAS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ELDORADO NATIONAL - KANSAS, INC. in 1655 WALL ST., SALINA, KS 67401 (NAICS 336211). OSHA activity number 340129808.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eldorado National - Kansas, INC. — free Get an email when a new federal OSHA severe-injury report for Eldorado National - Kansas, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1655 WALL ST.
City
SALINA
State
KS
ZIP
67401
Mailing
1655 WALL ST., SALINA, KS 67401
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336211
Employees
374
Ownership type
A

4 citations on file for this inspection.

1910.26 C02 VII

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 2, 2015
Abate by
Feb 27, 2015
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.26(c)(2)(vii): Ladders having defects were not marked and taken out of service until repaired:  Employees performing welding tasks were exposed to slip trip and fall hazards while using the three foot fiberglass step ladder in that the top step of the ladder was bent.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3000

1910.252 A02 III A 1

Serious Gravity 10 1 instance 25 exposed
Issued
Feb 2, 2015
Abate by
Feb 27, 2015
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.252(a)(2)(iii)(A)(1): The employer did not provide fire watchers whenever welding or cutting was performed, where appreciable combustible material in building construction or contents was closer than 35 feet (10.7 m) to the point of operation:  Employees cutting and welding vehicle bodies at weld station #3 were exposed to fire hazards.  The open gas tanks stored for re-installation back onto the vehicles were stored 7 feet away from welding and cutting areas.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.253 B04 III

Serious Gravity 5 1 instance 62 exposed
Issued
Feb 2, 2015
Abate by
Feb 27, 2015
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 1 hour:  Employees working on and near the van line were exposed to fire and explosion hazards.  The acetylene and oxygen tanks were stored in the same rack.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

1910.253 E01

Serious Gravity 5 2 instances 62 exposed
Issued
Feb 2, 2015
Abate by
Feb 27, 2015
Penalty
Initial $5,000 · Current $2,500 Reduced
29 CFR 1910.253(e)(1): Equipment was not installed and used only in the service for which it was approved and as recommended by the manufacturer:  Employees working in the van line were exposed to fire hazards in that regulator gauges were not installed and used as recommended by the manufacturer.  The gauges were damaged and still in use at the following locations:  a) The oxygen/acetylene pressure regulator gauge near the front of the car for the van weld prep station was missing the safety glass in the gauges.  b) The oxygen/acetylene pressure regulator gauge near the rear of the car for the van weld prep station was missing the safety glass in both the gauges. The acetylene gauge was missing pressure placard inside the gauge and the needle was missing so that it was not possible to determine what the actual pressure was for the acetylene regulator.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $5000

View Eldorado National - Kansas, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340129808.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.