ABBOTSFORD, WI —
OSHA Inspection: CREATIVE AUTOMATION, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of CREATIVE AUTOMATION, INC. in 102 WEST LINDEN STREET, ABBOTSFORD, WI 54405 (NAICS 333922). OSHA activity number 340130301.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CREATIVE AUTOMATION, INC.
- Site address
- 102 WEST LINDEN STREET
- City
- ABBOTSFORD
- State
- WI
- ZIP
- 54405
- Mailing
- P.O. BOX 505, ABBOTSFORD, WI 54405
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333922
- Employees
- 36
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.106 E02 IV A
- Issued
- Jun 1, 2015
- Abate by
- Jun 11, 2015
- Penalty
- Initial $4,200 · Current $4,200
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(a): 29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degrees F (37.8 degrees C), were not kept in covered containers when not actually in use: (a) Spray finishing and assembly areas; Containers of toluene were not covered between each use.
Recent events (1)
- — Z (S) $4200
1910.106 E09 III
- Issued
- Jun 1, 2015
- Abate by
- Jun 11, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: (a) Spray finishing area; Flammable storage containers were not emptied daily.
Recent events (1)
- — Z (S) $0
1910.134 C01
- Issued
- Jun 1, 2015
- Abate by
- Jul 7, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) Painting/Spray finishing area; A written respiratory protection program was not developed and implemented before employee(s) were required to wear full-face respirators.
Recent events (1)
- — Z (S) $2800
1910.134 E01
- Issued
- Jun 1, 2015
- Abate by
- Jul 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Painting/Spray finishing area; Medical evaluation(s) were not performed before employee(s) wore full-face respirator(s).
Recent events (1)
- — Z (S) $0
1910.134 F02
- Issued
- Jun 1, 2015
- Abate by
- Jul 7, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) Painting/Spray finishing area; Fit testing was not performed before an employee wore a full-face respirator.
Recent events (1)
- — Z (S) $0
1910.134 K03
- Issued
- Jun 1, 2015
- Abate by
- Jul 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: (a) Painting/Spray finishing area; Respirator training was not provided before employees were required to wear full-face respirators during spray finishing operations.
Recent events (1)
- — Z (S) $0
1910.134 K06
- Issued
- Jun 1, 2015
- Abate by
- Jul 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) Throughout the facility; Appendix D information was not provided for and/or reviewed with employees who voluntarily used filtering face piece respirators.
Recent events (1)
- — Z (S) $0
1910.212 A01
- Issued
- Jun 1, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Fabricating area, drill presses; Guarding was not provided for chucks and flying metal chips.
Recent events (1)
- — Z (S) $2800
1910.333 C02
- Issued
- Jun 1, 2015
- Abate by
- Jun 29, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools: (a) Throughout the facility; Energized electrical work was performed by unqualified employees.
Recent events (1)
- — Z (S) $4900
1910.335 A01 I
- Issued
- Jun 1, 2015
- Abate by
- Jul 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: (a) Throughout the facility; Electrically rated personal protective equipment was not worn during troubleshooting and maintenance operations performed on energized electrical equipment.
Recent events (1)
- — Z (S) $0
1910.1200 H01
- Issued
- Jun 1, 2015
- Abate by
- Jul 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Throughout the facility; Training was not provided to inform employees of the Global Harmonization System changes for container labeling and safety data sheet (SDS) format.
Recent events (1)
- — Z (O) $0
More inspections at Creative Automation, INC.
View Creative Automation, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333922)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340130301.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.