Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: M & M MILLWORKS OF LOUISIANA, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of M & M MILLWORKS OF LOUISIANA, LLC in 999 TIDWELL RD., WEST MONROE, LA 71292 (NAICS 321911). OSHA activity number 340131333.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & M Millworks of Louisiana, LLC for free Get an email when a new federal OSHA severe-injury report for M & M Millworks of Louisiana, LLC is published. One employer, no account, unsubscribe in one click.
Site address
999 TIDWELL RD.
City
WEST MONROE
State
LA
ZIP
71292
Mailing
999 TIDWELL RD., WEST MONROE, LA 71292
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
8
Ownership type
Private (A)

1 citation on file for this inspection.

1910.303 G01 I A

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 13, 2015
Penalty
Initial $867 · Current $434 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    a.  The employer did not ensure that electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, that the depth of the working space in the direction of access to live parts was not less than indicated in Table S-1 of Subpart S of Part 1910.  This violation occurred on or about December 11, 2014, when the electrical service entrance and circuit breaker panels on the East side of the Door Shop building did not have at least three (3) feet of clearance in the direction of access as required in Table S-1.
Recent events (2)
  • · I (S) $433.5
  • · Z (S) $867

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340131333.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.