WEST MONROE, LA ·
OSHA Inspection: M & M MILLWORKS OF LOUISIANA, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of M & M MILLWORKS OF LOUISIANA, LLC in 999 TIDWELL RD., WEST MONROE, LA 71292 (NAICS 321911). OSHA activity number 340131333.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & M MILLWORKS OF LOUISIANA, LLC
- Site address
- 999 TIDWELL RD.
- City
- WEST MONROE
- State
- LA
- ZIP
- 71292
- Mailing
- 999 TIDWELL RD., WEST MONROE, LA 71292
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- Employees
- 8
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1910.303 G01 I A
- Issued
- Jan 13, 2015
- Penalty
- Initial $867 · Current $434 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: a. The employer did not ensure that electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, that the depth of the working space in the direction of access to live parts was not less than indicated in Table S-1 of Subpart S of Part 1910. This violation occurred on or about December 11, 2014, when the electrical service entrance and circuit breaker panels on the East side of the Door Shop building did not have at least three (3) feet of clearance in the direction of access as required in Table S-1.
Recent events (2)
- · I (S) $433.5
- · Z (S) $867