CHICAGO, IL —
OSHA Inspection: ASHLAND COLD STORAGE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ASHLAND COLD STORAGE in 1556 W. 43RD STREET, CHICAGO, IL 60609 (NAICS 493120). OSHA activity number 340131721.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASHLAND COLD STORAGE
- Site address
- 1556 W. 43RD STREET
- City
- CHICAGO
- State
- IL
- ZIP
- 60609
- Mailing
- 1556 W. 43RD STREET, CHICAGO, IL 60609
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493120
- Employees
- 61
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.119 D03 II
- Issued
- Jun 1, 2015
- Penalty
- Initial $3,273 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer shall document that equipment complies with recognized and generally accepted good engineering practices. On or about January 14, 2015, the employer did not document that its equipment complies with recognized and generally accepted good engineering practice according to the ASHRAE-15 and IIAR-2 ANSI Standards or equivalent. Examples include, but are not limited to: a. West end of building - Outside the "Southeast" and "West", engine room doors there were no visual and audible ammonia alarms. Also the meaning of each alarm was not marked by signs near the annunciators. b. West end of building - Inside the "West", engine room the were no audible ammonia alarms. Also the meaning of each alarm was not marked by signs near the annunciators. c. Mezzanine engine room - Remote control of the mechanical equipment in the refrigeration machinery room was not provided immediately outside the machinery room door solely for the purpose of shutting down the equipment in an emergency. d. Mezzanine engine room - Emergency shutdown procedures including precautions to be observed in case of breakdown, or leak, were not posted outside of each engine room, immediately adjacent to each door. e. Mezzanine engine room - The "North" double doors were not tight fitting, permitting passage of escaping ammonia to other work areas.
Recent events (2)
- — I (S) $1960
- — Z (S) $3273
More inspections in this industry (NAICS 493120)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340131721.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.