On , OSHA opened a referral health inspection of QUALICO PRECISION PRODUCTS, LLC in 1251 COUNTY ROAD 1217, MOBERLY, MO 65270 (NAICS 336340). OSHA activity number 340134055.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Qualico Precision Products, LLC — free Get an email when a new federal OSHA severe-injury report for Qualico Precision Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1251 COUNTY ROAD 1217
City
MOBERLY
State
MO
ZIP
65270
Mailing
2000 HIGHWAY 63 SOUTH, MOBERLY, MO 65270
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336340
Employees
48
Ownership type
A

2 citations on file for this inspection.

1910.106 E06 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 6, 2015
Penalty
Initial $4,000 · Current $2,800 Reduced
29 CFR 1910.106(e)(6)(ii):  Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.  (A)  At Qualico  Precision Inc.  Two drums with flammable products were not grounding or bonding. -
Recent events (2)
  • — I (S) $2800
  • — Z (S) $4000

1910.1200 F05 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 6, 2015
Abate by
Jan 21, 2015
Penalty
Initial $4,000 · Current $2,800 Reduced
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings:(a)(LOCATION)(IDENTIFY SPECIFIC CHEMICAL/PRODUCT, SPECIFIC OPERATIONS AND DESCRIPTION OF EMPLOYEE EXPOSURE, AND CONDITION OF USE)  (a)  At the receiving area: Two holding tank with Film Kut 232, an industrial oil were not label with all the information required like flammability, health and reactivity risk.