SAPULPA, OK ·
OSHA Inspection: BENNETT STEEL FABRICATION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BENNETT STEEL FABRICATION, INC. in 9353 N. RIDGE WAY, SAPULPA, OK 74066 (NAICS 332312). OSHA activity number 340134238.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BENNETT STEEL FABRICATION, INC.
- Site address
- 9353 N. RIDGE WAY
- City
- SAPULPA
- State
- OK
- ZIP
- 74066
- Mailing
- 2210 N. INDUSTRIAL RD., SAPULPA, OK 74066
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 34
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.106 D04 IV
- Issued
- Feb 24, 2015
- Abate by
- Apr 8, 2015
- Penalty
- Initial $3,060 · Current $1,836 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(iv): Each inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system designed to provide for a complete change of air within the room at least six times per hour: On or about December 9, 2014, and at times prior thereto, flammable liquids were stored in a paint storage and mixing room that did not have any type of gravity or mechanical exhaust ventilation system, exposing employees to fire hazards.
Recent events (2)
- · I (S) $1836
- · Z (S) $3060
1910.106 E06 II
- Issued
- Feb 24, 2015
- Abate by
- Mar 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: On or about December 10, 2014, and at times prior thereto, in the paint areas Class I flammable liquids were dispensed into a smaller container without being effectively grounded and bonded to electrically interconnect the containers, exposing employees to a fire hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.107 G05
- Issued
- Feb 24, 2015
- Abate by
- Apr 8, 2015
- Penalty
- Initial $3,060 · Current $1,836 Reduced
General-duty citation text
29 CFR 1910.107(g)(5): The use of solvents for cleaning operations was not restricted to those having flashpoints not less than 100 degrees F or solvents having flashpoints not less than those normally used in the spray operation: On or about December 10, 2014, and at times prior thereto, in the flammable storage room employees were using Methyl Ethyl Ketone (MEK) having flashpoint of 18 degrees F as a solvent for cleaning operations. Employees were exposed to fire hazards.
Recent events (2)
- · I (S) $1836
- · Z (S) $3060
1910.179 G01 V
- Issued
- Feb 24, 2015
- Abate by
- Mar 4, 2015
- Penalty
- Initial $3,060 · Current $1,836 Reduced
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions: On or about December 9, 2014, and at times prior thereto, an overhead crane remote control was observed having control buttons not clearly marked for identification and function. The employees were exposed to crushing and struck by hazards.
Recent events (2)
- · I (S) $1836
- · Z (S) $3060
1910.179 I
- Issued
- Feb 24, 2015
- Abate by
- Apr 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(i): Crane(s) equipped with a power traveling mechanism were not provided with a gong or other effective warning signal: On or about December 9, 2014, and at times prior to, overhead cranes were operated by a remote control devices and were not provided with the means (audible alarm or strobe light) to warn employees working in the areas when the cranes were moving. Employees were exposed to struck-by hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Feb 24, 2015
- Abate by
- Apr 8, 2015
- Penalty
- Initial $3,825 · Current $2,295 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, and moving parts: On or about December 10, 2014, and at times prior thereto, in the shear and brake areas a press brake was being used via two-hand control without proper guards provided in the front and on the sides to prevent body parts contacting point-of-operation during operation. Employees were exposed to amputation hazards.
Recent events (2)
- · I (S) $2295
- · Z (S) $3825
1910.304 B02
- Issued
- Feb 24, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(b)(2): Outlet devices had an ampere rating less than the load being served: On or about December 10, 2014, or at times prior thereto, in the break room area a microwave oven and a coffee maker were plugged into the same outlet device which had a current rating less than the load being served. This exposed employees to fire hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 332312)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340134238.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.