Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SERFASS CONSTRUCTION CO. INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SERFASS CONSTRUCTION CO. INC in 2051 BEVIN DR., ALLENTOWN, PA 18104 (NAICS 236220). OSHA activity number 340139377.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Serfass Construction CO. INC — free Get an email when a new federal OSHA severe-injury report for Serfass Construction CO. INC is published. One employer, no account, unsubscribe in one click.
Site address
2051 BEVIN DR.
City
ALLENTOWN
State
PA
ZIP
18104
Mailing
3764 MAUCH RD., ALLENTOWN, PA 18104
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
35
Ownership type
A

2 citations on file for this inspection.

1926.502 B01

Serious Gravity 5 1 instance 20 exposed
Issued
Jan 28, 2015
Penalty
Initial $2,529 · Current $1,897 Reduced
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:Note:  When employees are using stilts, the top edge height of the top rail, or equivalent member, shall be increased an amount equal to the height of the stilts.  a) 2051 Bevin Dr. Allentown, Pa., 1st Level, Elevator Chute -- On or about December 12, 2014, employees were installing HVAC ducts and running wire throughout a two-story commercial facility, while being exposed to an inadequately guardrailed elevator chute which was approximately  14 feet above a lower level.
Recent events (2)
  • — I (S) $1896.75
  • — Z (S) $2529

1926.502 B13

Serious Gravity 5 1 instance 11 exposed
Issued
Jan 28, 2015
Penalty
Initial $2,023 · Current $1,517 Reduced
29 CFR 1926.502(b)(13): When guardrail systems were used around holes which were used as access (such as ladderways), they were not provided with a gate, or were not so offset that a person could not walk directly into the hole:  a) 2051 Bevin Dr. Allentown, Pa., Mezzanine Area -- On or about December 12, 2014, employees were installing Heating, Ventilation, and Air Conditioning ducts and electrical wiring up in the mezzanine area, while being exposed to an unguarded floor opening which was approximately 10 feet above a lower level.
Recent events (2)
  • — I (S) $1517.25
  • — Z (S) $2023

View Serfass Construction CO. INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340139377.