OSHA Inspection: GC ELECTRIC COMPANY, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of GC ELECTRIC COMPANY, INC. in 2051 BEVIN DR., ALLENTOWN, PA 18104 (NAICS 238210). OSHA activity number 340139666.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GC Electric Company, INC. — free Get an email when a new federal OSHA severe-injury report for GC Electric Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2051 BEVIN DR.
City
ALLENTOWN
State
PA
ZIP
18104
Mailing
705 E. ROCK RD., ALLENTOWN, PA 18104
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
60
Ownership type
A

3 citations on file for this inspection.

1926.502 B01

Serious Gravity 5 1 instance 8 exposed
Issued
Feb 6, 2015
Penalty
Initial $2,975 · Current $3,500
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:     a) 2051 Bevin Dr. Allentown, Pa., 1st Level, Elevator shaft - On or about December 12, 2014, employees were performing electrical installation throughout a two-story commercial structure, while being exposed to an inadequately guarded elevator shaft opening, in that the top rail height was approximately 30 inches above the floor height, which created a fall hazard from 14 feet above a lower level.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $2975

1926.502 B03

Serious Gravity 5 1 instance 8 exposed
Issued
Feb 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:  a) 2051 Bevin Dr. Allentown, Pa., 1st Level, Elevator shaft - On or about December 12, 2014, employees were performing electrical installation throughout a two-story commercial structure, while being exposed to an inadequately guarded elevator shaft opening, the guardrail would displace under minimal hand pressure, which created a fall hazard from 14 feet above a lower level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 B13

Serious Gravity 5 1 instance 8 exposed
Issued
Feb 6, 2015
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1926.502(b)(13): When guardrail systems were used around holes which were used as access (such as ladderways), they were not provided with a gate, or were not so offset that a person could not walk directly into the hole:    a) 2051 Bevin Dr. Allentown, Pa., Mezzanine Area -- On or about December 12, 2014, employees were installing electrical wiring up in the mezzanine where a floor opening used for ladder access, approximately 10 feet above the lower level, was not guarded by a standard guardrail or equivalent.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2380

View GC Electric Company, INC.'s full OSHA safety record →