Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: AUTOMATIC PROTECTION SYSTEMS INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AUTOMATIC PROTECTION SYSTEMS INC in 1090 MAIN ST, PATERSON, NJ 07503 (NAICS 238220). OSHA activity number 340139765.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Automatic Protection Systems INC for free Get an email when a new federal OSHA severe-injury report for Automatic Protection Systems INC is published. One employer, no account, unsubscribe in one click.
Site address
1090 MAIN ST
City
PATERSON
State
NJ
ZIP
07503
Mailing
368 BROAD ST, KEYPORT, NJ 07735
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
14
Ownership type
Private (A)

2 citations on file for this inspection.

1926.405 J01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 30, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported:  a) Interior of building: Metal boxes used by employees to connect power equipment that were designed to be securely mounted, were not mounted exposing employees to electric shock, on or about 11/7/13.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

1926.1052 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 30, 2014
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge:  a) Interior Stairways: Employees were using an interior stairway that did not have a handrail to access the floors of a residential building, exposing employees to a fall hazard, on or about 11/7/14.
Recent events (2)
  • · I (S) $800
  • · Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340139765.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.