SCARBOROUGH, ME —
OSHA Inspection: IFCO SYSTEMS NORTH AMERICA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of IFCO SYSTEMS NORTH AMERICA, INC. in 7 WASHINGTON AVENUE, SCARBOROUGH, ME 04074 (NAICS 321920). OSHA activity number 340140300.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IFCO SYSTEMS NORTH AMERICA, INC.
- Site address
- 7 WASHINGTON AVENUE
- City
- SCARBOROUGH
- State
- ME
- ZIP
- 04074
- Mailing
- 7 WASHINGTON AVENUE, SCARBOROUGH, ME 04074
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 70
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.176 B
- Issued
- Jan 15, 2015
- Abate by
- Jan 26, 2015
- Penalty
- Initial $5,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: White Pallets Storage Area - The White Pallet stacks were unstable.
Recent events (2)
- — I (S) $4000
- — Z (S) $5000
1910.178 A04
- Issued
- Jan 15, 2015
- Abate by
- Jan 28, 2015
- Penalty
- Initial $5,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: At the Facility - Yale forklifts #1 & #2 back rests had in-house welds without the manufacturer's prior written approval.
Recent events (2)
- — I (S) $4000
- — Z (S) $5000
1910.178 M10
- Issued
- Jan 15, 2015
- Abate by
- Jan 26, 2015
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(m)(10): Load backrest extension(s) were not used on industrial trucks to minimize the hazard of rearward falling materials: Throughout the Facility - Pallets moved by the forklifts were stacked three high above the backrest and mast.
Recent events (2)
- — I (S) $0
- — Z (S) $5000
1910.178 Q01
- Issued
- Jan 15, 2015
- Abate by
- Jan 28, 2015
- Penalty
- Initial $5,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: In the following instances, power-operator industrial trucks not in safe operating condition were not taken out of service at the Washington Avenue facility: a) Yale forklift #1 - The left rear light was not working and was detached from the structure. b) Yale forklift #2 - The right front light did not work. On or about the week of 12/1/2014, the back rest was not properly maintained and fell off the operator drove the forks into a stack. c) Yale forklift #4 - The left rear light was not working and was detached from the structure. The left front light was not working. The emergency brakes were on the "soft side". d) Yale forklift #6 - The emergency brake did not work. e) Yale forklift #7 - The right rear light was not working.
Recent events (2)
- — I (S) $4000
- — Z (S) $5000
1910.178 Q10
- Issued
- Jan 15, 2015
- Abate by
- Jan 26, 2015
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(q)(10): Industrial trucks were not kept in a clean condition: Near the Repair Stations - The Yale forklift #4 engine compartment was covered with black dust.
Recent events (2)
- — I (S) $0
- — Z (S) $5000
1910.242 B
- Issued
- Jan 15, 2015
- Penalty
- Initial $5,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Dry Washing Booth - The compressed air from the gun was not reduced to less than 30 p.s.i.
Recent events (2)
- — I (S) $4000
- — Z (S) $5000
1910.303 B02
- Issued
- Jan 15, 2015
- Abate by
- Jan 28, 2015
- Penalty
- Initial $3,000 · Current $2,400 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment were not installed and used in accordance with any instructions included in the listing or labeling. In the following instances, portable powered tools were not used according to its listing or labeling: a) Repair Station #11 - The plug attached to the double insulated Bosch reciprocating saw was modified to a 120 volt three wire twist lock plug. In addition, the rubber boot was missing, exposing the metal frame which had 26 volts to ground. b) Repair Station #12 - The plug attached to the double insulated Bosch reciprocating saw was modified to a 120 volt three wire twist lock plug. In addition, the rubber boot separated and exposed a portion of the metal frame which had 28 volts to ground. c) Repair Station #3 - The plug attached to each double insulated SENCO screwdriver gun was modified to a 120 volt three wire twist lock plug. In addition, the gun's metal feed housing had 29 volts to ground. d) Repair Station #5 - The plug attached to each double insulated SENCO screwdriver gun was modified to a 120 volt three wire twist lock plug. In addition, the gun's metal feed housing had 12-25 volts to ground. e) Repair Station #6 - The plug attached to each double insulated SENCO screwdriver gun was modified to a 120 volt three wire twist lock plug. In addition, the gun's metal feed housing had 30 volts to ground. f) Repair Station #8 - The plug attached to each double insulated SENCO screwdriver gun was modified to a 120 volt three wire twist lock plug. In addition, the gun's metal feed housing had 4 volts to ground. g) Repair Station #9 - The plug attached to each double insulated SENCO screwdriver gun was modified to a 120 volt three wire twist lock plug. In addition, the 2 week old gun's metal feed housing had 9 volts to ground.
Recent events (2)
- — I (S) $2400
- — Z (S) $3000
1910.22 D01
- Issued
- Jan 15, 2015
- Abate by
- Jan 28, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. Mezzanine - The area used to store spare parts, office supplies, and miscellaneous items did not have a load rating.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Jan 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Spray Paint Booth - The Liquidtite conduit was separated from its connector exposing six insulated electrical conductors to physical damage.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ifco Systems North America, INC.
View Ifco Systems North America, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in ME
Source