Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FABRIC DEVELOPMENT, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FABRIC DEVELOPMENT, INC. in 1217 MILL STREET, QUAKERTOWN, PA 18951 (NAICS 313210). OSHA activity number 340143411.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fabric Development, INC. — free Get an email when a new federal OSHA severe-injury report for Fabric Development, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1217 MILL STREET
City
QUAKERTOWN
State
PA
ZIP
18951
Mailing
P.O. BOX 462, QUAKERTOWN, PA 18951
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313210
Employees
100
Ownership type
A

9 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 1 1 instance 6 exposed
Issued
Mar 10, 2015
Abate by
Apr 3, 2015
Penalty
Initial $1,785 · Current $1,339 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Throughout Facility - On or about December 27, 2014, employee engaged in servicing and maintaining equipment with hazardous energy sources where specific procedures were not developed for the control of hazardous energy.  Abatement Note: The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: 1.  A specific statement of the intended use of the procedure; Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; 2.  Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and 3.  Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
Recent events (2)
  • — I (S) $1338.75
  • — Z (S) $1785

1910.147 C07 I

Serious Gravity 1 1 instance 6 exposed
Issued
Mar 10, 2015
Abate by
Apr 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  (a) Throughout Facility - On or about December 17, 2014 each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.   (b) Throughout Facility - On or about December 27, 2014, where a servicing and maintenance was conducted on machinery and equipment with hazardous energy sources, each affected employee was not instructed in the purpose and use of the energy control procedure.   (C) Throughout Facility - On or about December 27, 2014, all other employees whose work operations are or may be in an area where energy control procedures may be utilized, were not instructed about the procedure, and about the prohibition relating to attempts to restart or reenergize machines or equipment which are locked out or tagged out.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 A03

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 10, 2015
Abate by
Apr 12, 2015
Penalty
Initial $2,975 · Current $2,231 Reduced
29 CFR 1910.219(a)(3): The sides and face sections nip points of the drive belt(s) and pulley(s) of textile machinery were not guarded by a guard which extended at least six inches beyond the rim of the pulley on the in-running and off-running sides of the belt and at least two inches away from the rim and face of the pulley in all other directions:  (a) Plant 1 & 4 - On or about December 17, 2014, employees were exposed to hazards created by unguarded portions of the power transmission of the shuttle looms, to include but not limited to belts and pulleys.
Recent events (2)
  • — I (S) $2231.25
  • — Z (S) $2975

1910.219 B01

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 10, 2015
Abate by
Apr 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv)(  (a) Plant 1 & 4 - On or about December 17, 2014, employees were exposed to hazards created by unguarded portions of the power transmission of the shuttle looms, to include but not limited to flywheels
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F01

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 10, 2015
Abate by
Apr 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii):  (a) Plant 1 & 4 - On or about December 17, 2014, employees were exposed to hazards created by unguarded portions of the power transmission of the shuttle looms, to include but not limited to gears.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 10, 2015
Abate by
Apr 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:  (a) Plant 1 & 4 - On or about December 17, 2014, employees were exposed to hazards created by unguarded portions of the power transmission of the shuttle looms, to include but not limited to chains and sprockets.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.262 C05

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 10, 2015
Abate by
Apr 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.262(c)(5): All guards and safety devices, including starting and stopping device were not properly maintained  (a) Plant 1 & 4 - On or about December 17, 2014, the employer did not ensure that all machine guards were properly maintained in that, moveable guards were observed to be damaged, not installed, or completely missing, thereby exposing employees to hazards created by the moving parts of the power transmission of shuttle looms.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 100 exposed
Issued
Mar 10, 2015
Abate by
Apr 3, 2015
Penalty
Initial $1,785 · Current $1,339 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a)  Plant 2 - On or about December 17, 2014, no less than two flexible cords are connected in series to power a Dornier Weaving Machine (#D-9).  (b) Plant 4 - On or about December 17, 2014, at the IWER Weaver Machine (#IW-7), a portable radiant heater unit is is wired directly into a fuse box with a Type SOO flexible cord, Super-Trex Ultra-Gard Portable Cord.
Recent events (2)
  • — I (S) $1338.75
  • — Z (S) $1785

1910.305 G01 III

Serious Gravity 1 1 instance 100 exposed
Issued
Mar 10, 2015
Abate by
Apr 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iii): Flexible cords used as permitted in paragraphs (g)(1)(ii)(C), (g)(1)(ii)(G), or (g)(1)(ii)(I) of 29 CFR 1910.305 were not equipped with an attachment plug and energized from an approved receptacle outlet:   (a) Plant 4 - On or about December 17, 2014, at the IWER Weaver Machine (#IW-7), a portable radiant heater unit is not equipped with an attachment plug, nor was it energized from an approved receptacle outlet, in that the heater is wired directly into a fuse box with a Type SOO flexible cord, Super-Trex Ultra-Gard Portable Cord.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Fabric Development, INC.'s full OSHA safety record →