Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONTRACTORS IMPERIAL SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CONTRACTORS IMPERIAL SERVICES, INC. in 1700 W CLEVELAND ST., TAMPA, FL 33613 (NAICS 238350). OSHA activity number 340146075.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Contractors Imperial Services, INC. — free Get an email when a new federal OSHA severe-injury report for Contractors Imperial Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1700 W CLEVELAND ST.
City
TAMPA
State
FL
ZIP
33613
Mailing
13802 CYPRESS WAY SUITE 101, TAMPA, FL 33613
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
12
Ownership type
A

6 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Jan 5, 2015
Abate by
Jan 15, 2015
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   a) For the jobsite at 1700 W Cleveland St, Tampa, FL as observed on or about 12/17/2014, employees were exposed to fall hazards of over 50 ft. to the ground while installing trusses and doing framing work and fall hazards of 9 feet to the floor below. Fall protection was not being used, infeasibility was not shown, and a fall protection plan meeting the requirements of 1926.502(k) was not available and being used. The fall protection plan used by the employer was deficient in the following areas:  1) The fall protection plan was not developed specifically for the site 2) The fall protection plan did not include changes that were made 3) The fall protection plan did not document the reasons why the uses of conventional fall protection systems are infeasible or why they would create a greater hazard. 4) The fall protection plan did not identify each location where conventional fall protection methods cannot be used 5) The fall protection plan did not include a statement which provides the name or other method of identification for each employee who is designated to work in the controlled access zones.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.502 K01

Serious Gravity 10 1 instance 6 exposed
Issued
Jan 5, 2015
Abate by
Jan 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(k)(1): The fall protection plan shall be prepared by a qualified person and developed specifically for the site where the leading edge work, precast concrete work, or residential construction work is being performed and the plan must be maintained up to date.  a) For the residential apartment complex being constructed at 1700 W Cleveland St., Tampa, FL, as observed on or about 12/17/2014, employees were observed installing trusses over 50 feet off the ground without using conventional fall protection.  The fall protection plan in use was not specifically developed for the site.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 K03

Serious Gravity 10 1 instance 6 exposed
Issued
Jan 5, 2015
Abate by
Jan 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(k)(3): 29 CFR 1926.502(k)(3):  A copy of the fall protection plan with all approved changes was not maintained at the job site.  a) For the residential apartment complex being constructed at 1700 W Cleveland St., Tampa, FL, as observed on or about 12/17/2014, employees were working at heights of over 50 feet installing trusses without conventional fall protection. Changes in work practices that deviated from the written plan on site were implemented in that employees worked at heights of over 50 feet without using conventional fall protection and the employer's fall protection plan was only developed for working at heights of 48 feet or below. These changes were not included in the employer's fall protection plan.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 K05

Serious Gravity 10 1 instance 6 exposed
Issued
Jan 5, 2015
Abate by
Jan 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(k)(5): The fall protection plan did not document the reasons why the use of conventional fall protection systems (guardrail systems, personal fall arrest systems, or safety nets systems) are infeasible or why their use would create a greater hazard.  a) For the residential apartment complex being constructed at 1700 W Cleveland St., Tampa, FL, as observed on or about 12/17/2014, employees were using a fall protection plan that did not document the reasons why the use of conventional fall protection systems are infeasible or why their use would create a greater hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 K07

Serious Gravity 10 1 instance 6 exposed
Issued
Jan 5, 2015
Abate by
Jan 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(k)(7): The fall protection plan did not identify each location where conventional fall protection methods cannot be used, these locations were not then classified as controlled access zones having to comply with the criteria of paragraph (g) of this section.  a) For the residential apartment complex being constructed at 1700 W Cleveland St., Tampa, FL, as observed on or about 12/17/2014, employees were observed installing trusses at a height of over 50 feet from ground level. The fall protection plan in use on the site did not identify each location where methods of conventional fall protection cannot be used, and controlled access zones were not clearly identified.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 K09

Serious Gravity 10 1 instance 6 exposed
Issued
Jan 5, 2015
Abate by
Jan 15, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(k)(9): The fall protection plan did not include a statement which provides the name or other method of identification for each employee who is designated to work in controlled access zones.  a) For the residential apartment complex being constructed at 1700 W Cleveland St., Tampa, FL, as observed on or about 12/17/2014, the fall protection plan in use on the site did not identify each employee designated to work in the controlled access zones.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Contractors Imperial Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340146075.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.