Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SALEM KOBROSSLY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SALEM KOBROSSLY in 110 EAST MEDICAL CENTER BLVD., WEBSTER, TX 77598 (NAICS 238140). OSHA activity number 340147115.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Salem Kobrossly — free Get an email when a new federal OSHA severe-injury report for Salem Kobrossly is published. One employer, no account, unsubscribe in one click.
Establishment
SALEM KOBROSSLY
Site address
110 EAST MEDICAL CENTER BLVD.
City
WEBSTER
State
TX
ZIP
77598
Mailing
18710 MOONLIT POND COURT, HOUSTON, TX 77084
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.451 G02

Other-than-serious 1 instance 3 exposed
Issued
Feb 11, 2015
Abate by
Feb 22, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.451(g)(2): The employer did not have a competent person determine the feasibility and safety of providing fall protection for employees erecting or dismantling supported scaffolds:    a) At the site, the competent person determining the feasibility and safety of providing fall protection for employees erecting or dismantling supported scaffolds was not competent in that he did not know the shock load capacity of the rope; he did not know that the anchor point cannot be attached to a platform; and he did not know if tying the rope into a knot around the scaffold was adequate as an anchor point.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2800

1926.451 G03

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 11, 2015
Abate by
Feb 18, 2015
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.451(g)(3): Fall arrest systems used on scaffolds did not meet the requirements of 29 CFR 1926.502(d):    a) At the site, snap hooks of the personal fall arrest system being used with tubular welded frame scaffolding were connected directly to webbing, rope or wire rope, exposing employees to fall hazards of  approximately 25 feet.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1926.451 G03 I

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 11, 2015
Abate by
Feb 18, 2015
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage independent of the scaffold:    a) At the worksite, the personal fall arrest systems being used with tubular welded frame scaffolding was anchored to the end frames of the scaffold
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

View Salem Kobrossly's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340147115.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.