Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: MORNINGSTAR PROPERTIES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MORNINGSTAR PROPERTIES, LLC in 1920 LAKESHORE DRIVE, MUSKEGON, MI 49441 (NAICS 713930). OSHA activity number 340148097.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Morningstar Properties, LLC — free Get an email when a new federal OSHA severe-injury report for Morningstar Properties, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1920 LAKESHORE DRIVE
City
MUSKEGON
State
MI
ZIP
49441
Mailing
1920 LAKESHORE DRIVE, MUSKEGON, MI 49441
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713930
Employees
32
Ownership type
A

7 citations on file for this inspection.

1910.37 A03

Other-than-serious 1 instance 9 exposed
Issued
Feb 3, 2015
Penalty
Initial $1,785 · Current $700 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    In the rear of building 3, fire exit leading out of the building blocked by two sailboat masts positioned outside the exit door.
Recent events (2)
  • — I (O) $700
  • — Z (S) $1785

1910.37 B02

Other-than-serious 4 instances 9 exposed
Issued
Feb 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":    a. In building 1, two exit leading out of the building was not marked by a sign reading "Exit".    b. In building 2, one exit leading out of the building was not marked by a sign reading "Exit".    c. In building 3, one exit leading out of the building was not marked by a sign reading "Exit".
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.37 B06

Other-than-serious 3 instances 9 exposed
Issued
Feb 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:    a. In building 1, two exit leading out of the building were not illuminated by a reliable light source.    b. In building 2, one exit leading out of the building were not illuminated by a reliable light source.    c. In building 3, one exit leading out of the building were not illuminated by a reliable light source.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.179 B05

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 3, 2015
Abate by
Mar 23, 2015
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.179(b)(5): Crane(s) with more than one hoisting unit did not have the rated load marked on each hoisting unit or load block:    Great Lakes Marina and Storage, 50 ton Marine Travelift, Model # 50-BFM, S/N 2336889 did not have rated load markings on each hoisting unit or load block exposing employees to struck against, struck by, caught between or under hazards associated when moving a 32 foot boat onto a commercial truck from storage.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.179 M01

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 3, 2015
Abate by
Mar 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.179(m)(1): Thorough monthly inspections of rope conditions, with written, dated and signed reports, were not performed on the running ropes:   The employer did not conduct monthly running rope inspections and did not maintain a written certification record for running rope inspection for 50 ton Marine Travelift, Model # SP50H, S/N 102930217.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 3, 2015
Penalty
Initial $2,380 · Current $1,666 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:     In building 3 1/2, next to the Ingersoll-Rand air compressor, the employer did not ensure unused openings in circuit breaker panel were covered, there by shock and or fire hazard.
Recent events (2)
  • — I (S) $1666
  • — Z (S) $2380

1915.502 A

Other-than-serious 1 instance 9 exposed
Issued
Feb 3, 2015
Abate by
Mar 23, 2015
Penalty
Initial $1,785 · Current $700 Reduced
29 CFR 1915.502(a): A written fire safety plan was not developed and implemented by the employer that covered all of the actions necessary to ensure the employees safety in the event of a fire.     The employer did not develop and implement an adequate fire safety plan that covered all of the actions necessary to ensure employees safety in the event of a fire. Significant fire hazards include but are not limited to: Flammable Gas, Hazardous chemicals, Fuel vapors from boats in storage, storage of marine batteries, and combustible materials.
Recent events (2)
  • — I (O) $700
  • — Z (S) $1785

View Morningstar Properties, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340148097.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.