Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: B.I.A. CONTRACTORS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of B.I.A. CONTRACTORS LLC in 924 NORTH CAROLINA AVE SE, WASHINGTON, DC 20003 (NAICS 236115). OSHA activity number 340150440.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch B.I.A. Contractors LLC for free Get an email when a new federal OSHA severe-injury report for B.I.A. Contractors LLC is published. One employer, no account, unsubscribe in one click.
Site address
924 NORTH CAROLINA AVE SE
City
WASHINGTON
State
DC
ZIP
20003
Mailing
5206 19TH ROAD N, ARLINGTON, VA 22207
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
12
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 5, 2015
Abate by
Feb 11, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) Front Center Roof Top of Structure - The workers  on the roof removing old roofing materials were not protected from falling approximately 25 feet to the concrete walkway, on or about 12/17/2014.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Feb 5, 2015
Abate by
Feb 11, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a) Front Center Rooftop of Structure -  The ladder workers used to gain access to the roof from the ground extended approximately 1.5 feet above access landing on or about 12/17/14.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • · Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340150440.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.