Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: CONCEPT BOATS, INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CONCEPT BOATS, INC in 2410 NW 147TH STREET, OPA LOCKA, FL 33054 (NAICS 336612). OSHA activity number 340150770.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Concept Boats, INC for free Get an email when a new federal OSHA severe-injury report for Concept Boats, INC is published. One employer, no account, unsubscribe in one click.
Establishment
CONCEPT BOATS, INC
Site address
2410 NW 147TH STREET
City
OPA LOCKA
State
FL
ZIP
33054
Mailing
2410 NW 147TH STREET, OPA LOCKA, FL 33054
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
20
Ownership type
Private (A)

14 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
May 20, 2015
Abate by
Jun 9, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards. Note: Toeboards are only required when persons can pass under the platform, there is moving equipment, or there is equipment with which falling materials could create a hazard.  On or about December 17, 2014, at the above addressed jobsite, the employer did not provide the two platforms a standard railings for employees who are exposed to a working surfaces approximately 5 feet and 1 and one-half inches (61.5 inches) above the concrete floor below.
Recent events (1)
  • · Z (S) $2000

1910.23 D01 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 20, 2015
Abate by
Jun 9, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.23(d)(1)(ii): Stairway(s) less than 44 inches wide having one side open, did not have at least one stair railing on the open side:  On or about December 17, 2014, at the above addressed jobsite, the employer did provide stair railing to prevent a fall hazard for employees who are required to ascend and descend 5 feet 1 and one-half inches (61.5 inches) above the concrete floor below.
Recent events (1)
  • · Z (S) $2000

1910.36 D01

Serious Gravity 5 1 instance 4 exposed
Issued
May 20, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  On or about February 23, 2015, at the above addressed jobsite, the employer did not maintain exit doors open, two exit doors located on the east side and one exit on the north side near the overhead door in the northeast corner of the building, were locked.
Recent events (1)
  • · Z (S) $2000

1910.37 A03

Serious Gravity 5 1 instance 4 exposed
Issued
May 20, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  On or about February 23, the exit routes of the east side of the building were obstructed with boat parts and wood debris that impeded the exit of employees.
Recent events (1)
  • · Z (S) $2000

1910.106 E06 I

Serious Gravity 5 1 instance 10 exposed
Issued
May 20, 2015
Abate by
Jun 16, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors:  On or about December 17, 3014, at the above addressed jobsite, the employer did not ground the resin (a Category 3 flammable) caddies, exposing employees to a fire hazard.
Recent events (1)
  • · Z (S) $2000

1910.178 L

Serious Gravity 5 1 instance 5 exposed
Issued
May 20, 2015
Abate by
Jul 8, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks:  On or about December 17, 2014, at the above addressed jobsite, the employer did not train employees who are required to operate the powered industrial truck in the safe operation.
Recent events (1)
  • · Z (S) $2000

1910.178 P01

Serious Gravity 5 1 instance 5 exposed
Issued
May 20, 2015
Abate by
Jul 8, 2015
Penalty
Initial $1,600 · Current $1,600

Hazardous substances 2150

29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):(  On or about February 23, 2015, at the above addressed jobsite, employees were exposed to a defective Clark forklift, serial number 355-1811-2572 in that:  a) The fuel line from the propane tank had exposed braiding that could allow liquid propane (LP) to escape and be ignited.  b) Tank straps to secure the liquid propane (LP) tank in place were missing.
Recent events (1)
  • · Z (S) $1600

1910.134 C

Other-than-serious 1 instance 15 exposed
Issued
May 20, 2015
Abate by
Jul 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:  On or about November 17, 2015, at the above addressed jobsite, the employer did not implement a written respirator protection program for employees who are required to wear 3M 1/2 mask elastomeric, 3M full face, and N95 filtering-face piece respirators.
Recent events (1)
  • · Z (O) $0

1910.134 E01

Other-than-serious 1 instance 15 exposed
Issued
May 20, 2015
Abate by
Jul 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Note:  The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.  On or about December 17, 2014, at the above addressed jobsite, the employer did not provide medical evaluations to determine the employees' ability to wear 3M full-face and 3M 1/2 mask elastomeric respirators.
Recent events (1)
  • · Z (O) $0

1910.134 F01

Other-than-serious 1 instance 15 exposed
Issued
May 20, 2015
Abate by
Jul 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  On or about December 17, 2014, at the above addressed jobsite, the employer did not provide  employees who are required to wear a 3M full-face and 3M 1/2 mask tight-fitting facepiece respirators a fit test to determine the effectiveness of the respirator being used.
Recent events (1)
  • · Z (O) $0

1910.134 K03

Other-than-serious 1 instance 15 exposed
Issued
May 20, 2015
Abate by
Jul 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  On or about February 23, 2015, at the above addressed jobsite, the employer did not train employees who are required to use a 3M full-face and 3M 1/2 mask elastomeric respirator prior to work assignment.
Recent events (1)
  • · Z (O) $0

1910.179 G01 V

Other-than-serious 2 instances 4 exposed
Issued
May 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions:  On or about February 23, 2015, the buttons of the pendant control boxes for the cranes in the lamination area were covered with overspray and dust to the extent the function of buttons of the crane control was not  illegible.
Recent events (1)
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 15 exposed
Issued
May 20, 2015
Abate by
Jul 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):  On or about December 17, 2014, at the above addressed jobsite, the employer did not implement a written hazard communication program for the employees who are exposed hazardous chemicals such as, but not limited to, MEK, acetone, Isocyanates MDI polyaromatics resins, and styrene.
Recent events (1)
  • · Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 15 exposed
Issued
May 20, 2015
Abate by
Jul 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or about December 17, 2014, at the above addressed jobsite, the employer did not provide effective information and training to employees using hazardous chemicals such as, but not limited to, MEK, acetone, Isocyanates MDI polyaromatics resins, and styrene.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340150770.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.