LONGMEADOW, MA ·
OSHA Inspection: GREG CONNORS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GREG CONNORS in 33 ELLINGTON ST, LONGMEADOW, MA 01106 (NAICS 238160). OSHA activity number 340151364.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREG CONNORS
- Site address
- 33 ELLINGTON ST
- City
- LONGMEADOW
- State
- MA
- ZIP
- 01106
- Mailing
- 39 JESSIE LN, WESTFIELD, MA 01085
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- Jan 6, 2015
- Abate by
- Jan 12, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. a) 33 Ellington St., Longmeadow, MA: On or about December 22, 2014, 2 employees were observed roofing the garage being built at this address without any fall protection, more than 9 feet above the ground below.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.1053 B01
- Issued
- Jan 6, 2015
- Abate by
- Jan 12, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: a) 33 Ellington St., Longmeadow, MA: On or about December 22, 2014, 2 employees were observed climbing on a portable extension ladder that did not extend any distance past the upper landing surface they were using the ladder to access.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
More inspections in this industry (NAICS 238160)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340151364.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.