Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: ANDREW CASTELIAN

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANDREW CASTELIAN in 1805 HOBAN RD NW, WASHINGTON, DC 20006 (NAICS 238130). OSHA activity number 340163492.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Andrew Castelian for free Get an email when a new federal OSHA severe-injury report for Andrew Castelian is published. One employer, no account, unsubscribe in one click.
Establishment
ANDREW CASTELIAN
Site address
1805 HOBAN RD NW
City
WASHINGTON
State
DC
ZIP
20006
Mailing
1515 S. OAKLAND STREET, ARLINGTON, VA 22204
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 2 exposed
Issued
May 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On December 3, 2014 and at times prior thereto; upper platform; employees framing a new extension on a residential home were observed walking the outer edge of the platform without fall protection in place to prevent them from falling 25 feet to ground level.
Recent events (1)
  • · Z (S) $0

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
May 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed.   a) On December 3, 2014 and at times prior thereto; second floor north-side; the six foot step ladders used to access the platform area were not tall enough to extend three feet above the working platform exposing them to a 9 foot fall hazard while using the ladder to access the platform.
Recent events (1)
  • · Z (S) $0

1926.1053 B13

Serious Gravity 5 2 instances 2 exposed
Issued
May 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:   a) On December 3, 2014 and at times prior thereto; second floor north-side; the six foot step ladders used to access the platform area were not tall enough to extend three feet which resulted in the employees using the top step while accessing the platform area or while stretching from the platform area to access the top of the ladder; exposing employees to a fall hazard of 9 feet to the lower platform floor.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340163492.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.