Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BOSS PRECISION LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOSS PRECISION LTD. in 2440 SOUTH UNION STREET, SPENCERPORT, NY 14559 (NAICS 332322). OSHA activity number 340164268.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Boss Precision LTD. — free Get an email when a new federal OSHA severe-injury report for Boss Precision LTD. is published. One employer, no account, unsubscribe in one click.
Establishment
BOSS PRECISION LTD.
Site address
2440 SOUTH UNION STREET
City
SPENCERPORT
State
NY
ZIP
14559
Mailing
2440 SOUTH UNION STREET, SPENCERPORT, NY 14559
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
43
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 2 instances 8 exposed
Issued
Feb 6, 2015
Abate by
Mar 11, 2015
Penalty
Initial $2,975 · Current $2,231 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) On or about 01/06/15 in the Press Brake area; employer failed to protect employees during die changing from the unexpected release of hazardous energy ( caught between hazard ) by not requiring them to utilize the written Energy Procedures and the Lockout/Tagout Card,( i.e. the energy source to be shut off and locked out) during service and maintenance activities associated with the Amada brand press brakes, such as but not limited to, RG8024, model 100 and model 120.    b) On or about 01/26/15 in the Deburring area; employer failed to protect employees engaged in the belt changing on the Time Savers 1200 machine from the unexpected start up of this equipment ( caught between hazard ) by not requiring the energy sources ( electric and pneumatic ) to be locked out during this service and maintenance activity according to the Lockout/Tagout card which required lockout of the disconnect and the pneumatic devices.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2231.25
  • — Z (S) $2975

1910.147 C07 I A

Serious Gravity 5 2 instances 8 exposed
Issued
Feb 6, 2015
Abate by
Mar 11, 2015
Penalty
Initial $2,975 · Current $2,231 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the methods and means necessary for energy isolation;   a) On or about 01/06/15 in the Press Brake area; employer failed to train employees who performed the die changing on press brakes, such as but not limited to, Amada brand RG8024, model 100 and model 120, on the requirement to shut off the power ( isolating the machine from hazardous energy) and applying an energy control device ( lock ) to protect them from the unexpected release of hazardous energy ( caught between hazard ) prior to conducting such service and maintenance activities.   b) On or about 01/26/15 in the Deburring area; employer failed to train employees who performed the belt changing on the Time Savers 1200 machine on the requirement for applying an energy control device ( lock ) on the energy isolation devices ( electrical disconnect and pneumatic valve ) to protect them the unexpected start up of this equipment ( caught between hazard ) prior to conducting such service and maintenance activities.   ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2231.25
  • — Z (S) $2975

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Feb 6, 2015
Abate by
Mar 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) On or about 01/26/15 at column C3 in the Press Brake area; employer failed to protect employees against fire hazards by allowing the use of a relocatable power tap to be used to supply power to the electrical devices on Amada press brake 60 when a quad receptacle was in proximity to the power cords.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Boss Precision LTD.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340164268.