Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: T&G PLUMBING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of T&G PLUMBING in 3940 REDBLUFF, PASADENA, TX 77503 (NAICS 238220). OSHA activity number 340166651.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T&G Plumbing — free Get an email when a new federal OSHA severe-injury report for T&G Plumbing is published. One employer, no account, unsubscribe in one click.
Establishment
T&G PLUMBING
Site address
3940 REDBLUFF
City
PASADENA
State
TX
ZIP
77503
Mailing
2010 AHERNS, HOUSTON, TX 77017
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 5 2 instances 2 exposed
Issued
Feb 2, 2015
Abate by
Feb 6, 2015
Penalty
Initial $2,640 · Current $1,584 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a)  At the worksite, on January 7, 2015, employees working inside the excavation without head protection were exposed to falling rock, debris, and materials.
Recent events (2)
  • — I (S) $1584
  • — Z (S) $2640

1926.651 I01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 2, 2015
Abate by
Feb 6, 2015
Penalty
Initial $2,640 · Current $1,584 Reduced
29 CFR 1926.651(i)(1): Where the stability of adjoining buildings, walls, or other structures was endangered by excavation operations, support systems such as shoring, bracing or underpinning was not provided to ensure the stability of such structures for the protection of employees:  a)  At the worksite, on January 6, 2015, the stop sign post adjacent to the sidewall was not secured from falling into excavation.
Recent events (2)
  • — I (S) $1584
  • — Z (S) $2640

1926.651 K01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 2, 2015
Abate by
Mar 7, 2015
Penalty
Initial $3,080 · Current $1,848 Reduced
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems:    a)  At the worksite, on January 6, 2014, a competent person was not onsite to conduct daily inspections, evaluate situations that may result in cave-ins, or determine indications of failure of protective systems for the excavation.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3080

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 2, 2015
Abate by
Feb 6, 2015
Penalty
Initial $1,760 · Current $1,056 Reduced
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:  a)  At the worksite, on January 6, 2015, the ladder used for access and egress of the excavation was not long enough to extend at least 3 feet above the landing surface.
Recent events (2)
  • — I (S) $1056
  • — Z (S) $1760

1926.651 C02

Repeat Gravity 5 1 instance 2 exposed
Issued
Feb 2, 2015
Abate by
Feb 6, 2015
Penalty
Initial $4,400 · Current $2,640 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a)  At the worksite, on January 6, 2015, a ladder was not provided to the two employees working inside the excavation that measured approximately 8.8 feet deep.   T&G Plumbing was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.651(c)(2), which was contained in OSHA inspection number 988352, citation number 1, item number 1 and was affirmed as a final order on September 25, 2014, with respect to a workplace located at 1837 Broadway St., Pearland, TX 77581.
Recent events (2)
  • — I (R) $2640
  • — Z (R) $4400

1926.651 J02

Repeat Gravity 5 1 instance 2 exposed
Issued
Feb 2, 2015
Abate by
Feb 6, 2015
Penalty
Initial $5,280 · Current $3,168 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:  a)  At the worksite, on January 6, 2015, the spoil piles were located adjacent to the sidewalls of the excavation.   T&G Plumbing was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.651(j)(2), which was contained in OSHA inspection number 988352, citation number 1, item number 2 and was affirmed as a final order on September 25, 2014, with respect to a workplace located at 1837 Broadway St., Pearland, TX 77581.
Recent events (2)
  • — I (R) $3168
  • — Z (R) $5280

1926.652 A01

Repeat Gravity 10 1 instance 2 exposed
Issued
Feb 2, 2015
Abate by
Feb 6, 2015
Penalty
Initial $6,160 · Current $3,696 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c):      a)  At the worksite, on January 6, 2015, two employees were working inside an excavation that measured approximately 8.8 feet deep without any protection from cave-ins.   T&G Plumbing was previously cited for a violation of this occupational safety and health standard 29 CFR 1926.652(a)(1), which was contained in OSHA inspection number 988352, citation number 1, item number 3 and was affirmed as a final order on September 25, 2014, with respect to a workplace located at 1837 Broadway St., Pearland, TX 77581.
Recent events (2)
  • — I (R) $3696
  • — Z (R) $6160

View T&G Plumbing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340166651.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.