NORTH ARLINGTON, NJ —
OSHA Inspection: J.C WATSON'S CONSTRUCTION MODULAR SETUP
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of J.C WATSON'S CONSTRUCTION MODULAR SETUP in 65 SHUYLER AVENUE, NORTH ARLINGTON, NJ 07031 (NAICS 238350). OSHA activity number 340170083.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.C WATSON'S CONSTRUCTION MODULAR SETUP
- Site address
- 65 SHUYLER AVENUE
- City
- NORTH ARLINGTON
- State
- NJ
- ZIP
- 07031
- Mailing
- 189 BEECH FOREST ROAD, BEECH CREEK, PA 16822
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Mar 12, 2015
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. a) Roof of Residential Building- Employees working on the roof were not tied off and were exposed to a fall of approximately 33 feet to the ground below; on or about 1/7/2015.
Recent events (2)
- — I (S) $1540
- — Z (S) $3080
1926.1053 B01
- Issued
- Mar 12, 2015
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) Roof level- Employees were accessing a ladder that did not extend 3 feet over the landing; on or about 1/7/15.