PITTSBURGH, PA —
OSHA Inspection: VCA MET VET WEST
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of VCA MET VET WEST in 5309 CAMPBELLS RUN ROAD, PITTSBURGH, PA 15205 (NAICS 541940). OSHA activity number 340170133.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VCA MET VET WEST
- Site address
- 5309 CAMPBELLS RUN ROAD
- City
- PITTSBURGH
- State
- PA
- ZIP
- 15205
- Mailing
- 5309 CAMPBELLS RUN ROAD, PITTSBURGH, PA 15205
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541940
- Employees
- 30
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.132 D02
- Issued
- Jan 21, 2015
- Abate by
- Feb 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment: a) In the Facility, on or about January 9, 2015 - The employer did not perform a written personal protective equipment hazard assessment which describes the hazards that are present and which necessitate the need for personal protective equipment. Employees utilize personal protective equipment including but not limited to safety glasses, gloves and lead aprons.
Recent events (1)
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Jan 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): The employer did not ensure that flexible cords and cables were not used as a substitute for the fixed wiring of a structure: a) Employee Lounge Area, on or about January 9, 2015 - The refrigerator in the Employee Lounge did not have fixed wiring, rather, it was plugged into an extension cord.