FEDERAL HEIGHTS, CO —
OSHA Inspection: J & B REFURB
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of J & B REFURB in 2305 W 92ND AVENUE, FEDERAL HEIGHTS, CO 80260 (NAICS 238320). OSHA activity number 340173103.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & B REFURB
- Site address
- 2305 W 92ND AVENUE
- City
- FEDERAL HEIGHTS
- State
- CO
- ZIP
- 80260
- Mailing
- 425 S 28TH LANE, BRIGHTON, CO 80601
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.1101 E06
- Issued
- Feb 5, 2015
- Abate by
- Mar 12, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1101(e)(6): The employer did not ensure that all asbestos work performed within regulated areas was supervised by a competent person: (a)J & B Refurb, at 2305 W 92nd Avenue, Federal Heights, CO: On or about 11/19/14, J & B Refurb did not ensure that all asbestos work performed within regulated areas was supervised by a competent person. J & B Refurb performed demolition of drywall that had joint compound containing approximately two percent chrysotile asbestos. The joint compound was an asbestos containing material. This was Class II asbestos work. This condition exposed employees of J & B Refurb to an asbestos hazard. (b) J & B Refurb, at 2305 W 92nd Avenue, Federal Heights, CO: On or about 11/19/14, J & B Refurb did not ensure that all asbestos work performed within regulated areas was supervised by a competent person. J & B Refurb removed upper track for an accordion room divider from a ceiling containing "popcorn" surface texture. The ceiling surface texture was a presumed asbestos containing material. This work was Class III asbestos work. This condition exposed employees of J & B Refurb to an asbestos hazard.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.1101 K09 I
- Issued
- Feb 5, 2015
- Abate by
- Mar 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(k)(9)(i): The employer did not institute, at no cost to employees, a training program for all employees who were likely to be exposed in excess of the PEL and for all employees who performed Class I through IV asbestos operations: (a) J & B Refurb, at 2305 W 92nd Avenue, Federal Heights, CO: On or about 11/19/14, J & B Refurb did not institute, at no cost to employees, a training program for all employees who were likely to be exposed in excess of the PEL and for all employees who performed Class I through IV asbestos operations. J & B Refurb performed demolition of drywall that had joint compound containing approximately two percent chrysotile asbestos. The joint compound was an asbestos containing material. This was Class II asbestos work. Employees had not been provided Class II asbestos work training. This condition exposed employees of J & B Refurb to an asbestos hazard. (b) J & B Refurb, at 2305 W 92nd Avenue, Federal Heights, CO: On or about 11/19/14, J & B Refurb did not institute, at no cost to employees, a training program for all employees who were likely to be exposed in excess of the PEL and for all employees who performed Class I through IV asbestos operations. J & B Refurb removed upper track for an accordion room divider from a ceiling containing "popcorn" surface texture. The ceiling surface texture was a presumed asbestos containing material. This work was Class III asbestos work. Employees had not been provided Class III asbestos work training. This condition exposed employees of J & B Refurb to an asbestos hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1101 F02 I
- Issued
- Feb 5, 2015
- Abate by
- Mar 12, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation: (a)J & B Refurb, at 2305 W 92nd Avenue, Federal Heights, CO: On or about 11/19/14, J & B Refurb did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation. J & B Refurb performed demolition of drywall that had joint compound containing approximately two percent chrysotile asbestos. The joint compound was an asbestos containing material. This was Class II asbestos work. This condition exposed employees of J & B Refurb to an asbestos hazard. (b)J & B Refurb, at 2305 W 92nd Avenue, Federal Heights, CO: On or about 11/19/14, J & B Refurb did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation. J & B Refurb removed upper track for an accordion room divider from a ceiling containing "popcorn" surface texture. The ceiling surface texture was a presumed asbestos containing material. This work was Class III asbestos work. This condition exposed employees of J & B Refurb to an asbestos hazard. Abatement Note: A competent person is capable of identifying existing asbestos hazards in the workplace and capable of selecting the appropriate control strategy for asbestos exposure, and who has the authority to take prompt corrective measures to eliminate them. For Class II work, who has received training which meets the criteria of EPA's Model Accreditation Plan for supervisors. For Class III work, who has received training which meets the EPA requirements for training of local education agency maintenance and custodial staff as set forth at 40 CFR 763.92(a)(2).
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.1101 K03 I
- Issued
- Feb 5, 2015
- Abate by
- Mar 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(k)(3)(i): Before work in areas containing asbestos-containing material (ACM) and presumed asbestos-containing material (PACM) was begun, the employer did not identify the presence, location, and quantity of ACM and/or PACM, pursuant to paragraph (k)(1) of this section: (a) J & B Refurb, at 2305 W 92nd Avenue, Federal Heights, CO: On or about 11/19/14, before work in areas containing asbestos-containing material (ACM) and presumed asbestos-containing material (PACM) was begun, J & B Refurb did not identify the presence, location, and quantity of ACM and/or PACM, pursuant to paragraph (k)(1) of this section. J & B Refurb performed demolition of drywall that had joint compound containing approximately two percent chrysotile asbestos and removed upper track for an accordion room divider from a ceiling containing "popcorn" surface texture. The joint compound was ACM. The ceiling surface texture was PACM. This condition exposed employees of J & B Refurb to an asbestos hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238320)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340173103.