OSHA Inspection: A-Z APARTMENT BUILDING SUPPLY CORP.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A-Z APARTMENT BUILDING SUPPLY CORP. in 325 NORTH BROADWAY, YONKERS, NY 10701 (NAICS 236118). OSHA activity number 340173863.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A-Z Apartment Building Supply Corp. — free Get an email when a new federal OSHA severe-injury report for A-Z Apartment Building Supply Corp. is published. One employer, no account, unsubscribe in one click.
Site address
325 NORTH BROADWAY
City
YONKERS
State
NY
ZIP
10701
Mailing
829 WESTCHESTER AVENUE, BRONX, NY 10455
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
5
Ownership type
A

9 citations on file for this inspection.

1926.300 B04 II

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 22, 2015
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1926.300(b)(4)(ii): The point of operation of machine(s) whose operation exposed an employee to injury was not guarded:    On or about 1/2/15    Location: 325 North Broadway, Yonkers, NY 10701    a) Employees used a Hitachi C10FSH Chop/Miter saw that had the guard for the lower half of the saw blade wedged, with a piece of wood, in the retracted/open position leaving the lower section of the blade unguarded.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

1926.304 H01

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 22, 2015
Abate by
Jul 17, 2015
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut:    On or about 01/02/15    Location: 325 North Broadway, Yonkers, NY 10701    a) Employees used a Ryobi 10 inch crosscut table saw that did not hood guard covering the portion of the saw blade above the table.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

1926.404 B01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 22, 2015
Abate by
Jul 17, 2015
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    On or about 1/2/15    Location: 325 North Broadway, Yonkers, NY 10701    a) Ground Fault Circuit Interrupters or an assured equipment grounding was not used to protect employees using extension cords and electrical powered tools.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

1926.405 A02 II F

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 22, 2015
Abate by
Jul 17, 2015
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights were suspended by their electric cords when such lights and cords were not designed for suspension:    On or about 1/2/15    Location: 325 North Broadway, Yonkers, NY 10701    a) Temporary lighting was suspended by their electrical cords and draped over metal sprinkler system piping.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

1926.416 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 22, 2015
Penalty
Initial $2,800 · Current $1,450 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:     On or about 1/2/15     Location: 325 North Broadway, Yonkers, NY 10701     a) An extension cord with a damaged/cut outer insulating jacket and damaged/cut insulation on a inner conductor wire which exposed copper conductor was used by employees to provide power the office trailer on site.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $2800

1926.451 B05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2015
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length extended over its support more than 12 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end:    On or about 12/31/14    Location: 325 North Broadway, Yonkers, NY 10701    a) The work platform on a single frame tubular welded frame scaffold extended approximately 24 inches past its support.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2015
Penalty
Initial $2,000 · Current $1,100 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    On or about 12/31/14    Location: 325 North Broadway, Yonkers, NY 10701    a) Employees on a single frame tubular welded frame scaffold, positioned on a deck, near the edge, were not protected from falls of 11 feet to the ground  below on the west end of the scaffold.
Recent events (2)
  • — I (S) $1100
  • — Z (S) $2000

1926.454 A

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 22, 2015
Abate by
Jul 17, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  On or about 12/31/14  Location: 325 North Broadway, Yonkers, NY 10701  a) Employees working on a tubular welded frame scaffold were not trained in the hazards associated with working on a scaffold and the procedures for minimizing such hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 22, 2015
Penalty
Initial $2,800 · Current $1,450 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    On or about 12/31/14    Location: 325 North Broadway, Yonkers, NY 10701    a) An employee on a pitched door canopy roof was not protected from falls of 8'7" to the cement entrance stair landing below and 11' to the ground below by a guardrail system or any other type of fall protection system.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $2800

View A-Z Apartment Building Supply Corp.'s full OSHA safety record →