EVANS, GA —
OSHA Inspection: EVERGREEN TANK SOLUTIONS (ETS)
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of EVERGREEN TANK SOLUTIONS (ETS) in 4192 CROSSTOWNE COURT, EVANS, GA 30809 (NAICS 532490). OSHA activity number 340174580.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EVERGREEN TANK SOLUTIONS (ETS)
- Site address
- 4192 CROSSTOWNE COURT
- City
- EVANS
- State
- GA
- ZIP
- 30809
- Mailing
- 16441 SPACE CENTER BLVD STE D2, HOUSTON, TX 77058
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 532490
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.22 D01
- Issued
- Apr 27, 2015
- Abate by
- May 1, 2015
- Penalty
- Initial $7,000 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. On or about 1/12/2015 in the maintenance shop over the parts room area: The area over the parts room in the maintenance shop was used by the employer as a storage area for material such as but not limited to; engine stand, boxes of papers, and other material was not load approved and marked for the floor rating by an approved official.
Recent events (2)
- — I (S) $4500
- — Z (S) $7000
1910.178 P01
- Issued
- Apr 27, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $7,000 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) On or about 1/12/2015 at 4192 Crosstowne Court in Evans, Georgia: Where an employee operated a powered industrial truck with hydraulic leaks, oil leaks, and a damage air gauge. The employer failed to remove the powered industrial truck from service until the repairs could be made.
Recent events (2)
- — I (S) $4500
- — Z (S) $7000
1910.178 L04 III
- Issued
- Apr 27, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $1,000 · Current $1,000
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about 1/12/2015 at 4192 Crosstowne Court in Evans, Georgia: Employees operating the powered industrial truck daily to weekly to lift heavy metal containers and other material were not trained and reevaluated in the past three years.