Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LCG SALES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LCG SALES, INC. in 5410 W. ROOSEVELT RD. SUITE 231, CHICAGO, IL 60644 (NAICS 339999). OSHA activity number 340177658.

Watch LCG Sales, INC. — free Get an email when a new federal OSHA severe-injury report for LCG Sales, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
LCG SALES, INC.
Site address
5410 W. ROOSEVELT RD. SUITE 231
City
CHICAGO
State
IL
ZIP
60644
Mailing
5410 W. ROOSEVELT RD. SUITE 231, CHICAGO, IL 60644
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339999
Employees
37
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 4 instances 10 exposed
Issued
Abate by
Penalty
Initial $4200.00 · Current $3000.00 Reduced
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.    Production Area - On or about January 13, 2015, the employer failed to adequately guard the blades on four Rigid cut-off saws.,there-by exposing employees to cuts and lacerations.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4200

1910.303 G02 I

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $0.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means:    Shop area - On or about January 13, 2015, the main circuit breakers panel were not guarded or covered to protect employees from coming in contact with energized conductors.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340177658.