ATHENS, AL —
OSHA Inspection: FEDERAL-MOGUL POWERTRAIN, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of FEDERAL-MOGUL POWERTRAIN, INC. in 1500 FREEMAN AVENUE, ATHENS, AL 35613 (NAICS 339991). OSHA activity number 340177955.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FEDERAL-MOGUL POWERTRAIN, INC.
- Site address
- 1500 FREEMAN AVENUE
- City
- ATHENS
- State
- AL
- ZIP
- 35613
- Mailing
- 1500 FREEMAN AVENUE, ATHENS, AL 35613
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339991
- Employees
- 615
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.106 E02 IV A
- Issued
- Mar 9, 2015
- Penalty
- Initial $2,550 · Current $1,530 Reduced
0040
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(a): Flammable liquids were not kept in covered containers when not in use: (a) On or about 1/13/15 - Screen printer station 1, the solvent containing acetone ,RN-1057 MEK replacement, was observed in an open top plastic container. (b) On or about 1/13/15 - Screen printer station 2, the solvent containing acetone, RN-1057 MEK replacement, was observed in an open top plastic container.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
1910.106 E06 II
- Issued
- Mar 9, 2015
- Penalty
- Initial $0 · Current $0
0040
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were transferred from one container to another, and both containers were not effectively bonded and grounded to prevent discharge sparks of static electricity: (a) On or about 1/13/15 - Screen printer area - the flammable solvent RN-157 MEK Replacement was dispensed without bonding or grounding.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E09 III
- Issued
- Mar 9, 2015
- Penalty
- Initial $2,550 · Current $1,530 Reduced
0040
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: (a) On or about 1/13/15 - Screen printer station 1, rags contaminated with flammable solvent and combustible ink were placed in an open top plastic container. (b) On or about 1/13/15 - Screen printer station 2, rags contaminated with flammable solvent and combustible ink were placed in an open top plastic container.
Recent events (2)
- — I (S) $1530
- — Z (S) $2550
More inspections at Federal-Mogul Powertrain, INC.
View Federal-Mogul Powertrain, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339991)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340177955.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.