REDINGTON BEACH, FL —
OSHA Inspection: ABOVE ALL CAULKING AND WATERPROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ABOVE ALL CAULKING AND WATERPROOFING, INC. in 18320 GULF BLVD, REDINGTON BEACH, FL 33708 (NAICS 238140). OSHA activity number 340178128.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABOVE ALL CAULKING AND WATERPROOFING, INC.
- Site address
- 18320 GULF BLVD
- City
- REDINGTON BEACH
- State
- FL
- ZIP
- 33708
- Mailing
- 4150 114TH TERRACE NORTH, CLEARWATER, FL 33762
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 30
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.300 B01
- Issued
- Jan 29, 2015
- Abate by
- Feb 18, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a. On or about January 13, 2015, an employee was exposed to an amputation hazard while working with a Milwaukee Handheld Angle Grinder (Serial # B62AD08510182) that did not have the manufacturer's safety guard in place during operational use.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1926.451 D03 X
- Issued
- Jan 29, 2015
- Abate by
- Feb 18, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.451(d)(3)(x): Single tiebacks were installed at an angle: a. On or about January 13, 2015, employees were exposed to the hazard of falling approximately 60 feet while working from a suspended scaffold that was attached to a 7 story apartment building. The two outriggers that were being used to support the scaffold each had one wire rope tieback which was attached at an angle.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1926.451 G03 I
- Issued
- Jan 29, 2015
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion: a. On or about January 13, 2015, employees were exposed to the hazard of falling approximately 60 feet while working from a suspended scaffold. The lifelines that the exposed employees were utilizing as part of their personal fall arrest system were not protected from chaffing.
Recent events (2)
- — I (S) $1785
- — Z (S) $2975
1926.451 G03 IV
- Issued
- Jan 29, 2015
- Abate by
- Feb 18, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.451(g)(3)(iv): Vertical lifelines, independent support lines, and suspension ropes shall not be attached to each other, nor shall they be attached to or use the same point of anchorage, nor shall they be attached to the same point on the scaffold or personal fall arrest system: a: On or about January 13, 2015, employees were exposed to the hazard of falling approximately 60 feet while working from a suspended scaffold. The lifelines that the exposed employees were utilizing as part of their personal fall arrest system shared the same anchorage point with each other along with the two wire ropes that were being used to secure the tiebacks.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1926.451 D12 IV
- Issued
- Jan 29, 2015
- Abate by
- Feb 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(d)(12)(iv): Clips shall be inspected and retightened to the manufacturer's recommendations at the start of each workshift thereafter: a. On or about January 13, 2015, the supervisor did not ensure the wire rope clips used to secure the tiebacks as part of a suspended scaffold were inspected and checked for the required tightness before each work shift.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Above ALL Caulking and Waterproofing, INC.
View Above ALL Caulking and Waterproofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340178128.