OSHA Inspection: ABOVE ALL CAULKING AND WATERPROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ABOVE ALL CAULKING AND WATERPROOFING, INC. in 18320 GULF BLVD, REDINGTON BEACH, FL 33708 (NAICS 238140). OSHA activity number 340178128.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Above ALL Caulking and Waterproofing, INC. — free Get an email when a new federal OSHA severe-injury report for Above ALL Caulking and Waterproofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
18320 GULF BLVD
City
REDINGTON BEACH
State
FL
ZIP
33708
Mailing
4150 114TH TERRACE NORTH, CLEARWATER, FL 33762
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
30
Ownership type
A

5 citations on file for this inspection.

1926.300 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 29, 2015
Abate by
Feb 18, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:  a. On or about January 13, 2015, an employee was exposed to an amputation hazard while working with a Milwaukee Handheld Angle Grinder (Serial # B62AD08510182) that did not have the manufacturer's safety guard in place during operational use.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1926.451 D03 X

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2015
Abate by
Feb 18, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.451(d)(3)(x): Single tiebacks were installed at an angle:   a. On or about January 13, 2015, employees were exposed to the hazard of falling approximately 60 feet while working from a suspended scaffold that was attached to a 7 story apartment building. The two outriggers that were being used to support the scaffold each had one wire rope tieback which was attached at an angle.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1926.451 G03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2015
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1926.451(g)(3)(i): Vertical lifelines were not fastened to a fixed safe point of anchorage, independent of the scaffold, and protected from sharp edges and abrasion:   a. On or about January 13, 2015, employees were exposed to the hazard of falling approximately 60 feet while working from a suspended scaffold. The lifelines that the exposed employees were utilizing as part of their personal fall arrest system were not protected from chaffing.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1926.451 G03 IV

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 29, 2015
Abate by
Feb 18, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1926.451(g)(3)(iv): Vertical lifelines, independent support lines, and suspension ropes shall not be attached to each other, nor shall they be attached to or use the same point of anchorage, nor shall they be attached to the same point on the scaffold or personal fall arrest system:  a: On or about January 13, 2015, employees were exposed to the hazard of falling approximately 60 feet while working from a suspended scaffold. The lifelines that the exposed employees were utilizing as part of their personal fall arrest system shared the same anchorage point with each other along with the two wire ropes that were being used to secure the tiebacks.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1926.451 D12 IV

Other-than-serious 2 instances 2 exposed
Issued
Jan 29, 2015
Abate by
Feb 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(12)(iv): Clips shall be inspected and retightened to the manufacturer's recommendations at the start of each workshift thereafter:   a. On or about January 13, 2015, the supervisor did not ensure the wire rope clips used to secure the tiebacks as part of a suspended scaffold were inspected and checked for the required tightness before each work shift.
Recent events (2)