On , OSHA opened a planned safety inspection of EURO DESIGN SOLUTIONS / MG4 in 3240 Q STREET, NW, WASHINGTON, DC 20007 (NAICS 236118). OSHA activity number 340178565.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Euro Design Solutions / MG4 — free Get an email when a new federal OSHA severe-injury report for Euro Design Solutions / MG4 is published. One employer, no account, unsubscribe in one click.
Site address
3240 Q STREET, NW
City
WASHINGTON
State
DC
ZIP
20007
Mailing
140 LITTLE FALLS STREET, #207, FALLS CHURCH, VA 22046
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
1
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2015
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) First Floor - Employees were working directly under a masonry operation and not wearing head protection, on or about 01/13/2015.    For the purpose of this inspection, this employer was determined to be the controlling and correcting employer on the job site. The employer is being cited under OSHAs multi-employer workplace policy.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 4, 2015
Abate by
Feb 10, 2015
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    a) First Floor - A laborer was using an extension cord to provide power to a DeWalt portable electric circular saw, model number DW368, and was not provided with a ground fault circuit interrupter or an assured equipment grounding conductor program, 120 volt, 15 amp service, on or about 01/13/2015.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.    For the purpose of this inspection, this employer was determined to be the controlling and correcting employer on the job site. The employer is being cited under OSHAs multi-employer workplace policy.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1926.451 G01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 4, 2015
Penalty
Initial $2,000 · Current $800 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    a) Second Story South Wall - Laborers were observed standing on a 32 inch wide saw horse scaffold work platform while attaching a 2 by 10 inch batter board to the face of the wall without fall protection and exposed to a 20 ft., 5 inch fall to the basement below, on or about 01/13/2015.    For the purpose of this inspection, this employer was determined to be the controlling and correcting employer on the job site. The employer is being cited under OSHAs multi-employer workplace policy.
Recent events (2)
  • — I (S) $800
  • — Z (S) $2000

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 4, 2015
Abate by
Feb 10, 2015
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) First Floor - Employees were observed standing on an 8 ft., by 8 ft. ladder landing that had not been provided with guardrails and exposed to an 11 ft., 5 inch fall hazard to the basement below, on or about 01/13/2015.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.    For the purpose of this inspection, this employer was determined to be the controlling and correcting employer on the job site. The employer is being cited under OSHAs multi-employer workplace policy.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340178565.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.