GNADENHUTTEN, OH —
OSHA Inspection: MCGUIRE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MCGUIRE INC. in 6295 STATE ROUTE 36, GNADENHUTTEN, OH 44629 (NAICS 332710). OSHA activity number 340178953.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCGUIRE INC.
- Site address
- 6295 STATE ROUTE 36
- City
- GNADENHUTTEN
- State
- OH
- ZIP
- 44629
- Mailing
- 303 TAYLOR AVE., DENNISON, OH 44621
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 11
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.24 H
- Issued
- Mar 6, 2015
- Abate by
- Sep 17, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.24(h): "Railings and handrails." Standard railings shall be provided on the open sides of all exposed stairways and stair platforms. Handrails shall be provided on at least one side of closed stairways preferably on the right side descending. Stair railings and handrails shall be installed in accordance with the provisions of 1910.23. a. In the 550 Area for Storage and Maintenance, the stairway platform to the upper storage area did not have a mid rail to protect employees when unloading storage materials thereby exposing employees to a ten foot fall hazard.
Recent events (3)
- — F (S) $1000
- — C (S) $2000
- — Z (S) $2000
1910.147 C06 I
- Issued
- Mar 6, 2015
- Abate by
- Jul 17, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a. In the plant where employees used lock-out/tag-out to service equipment for maintenance, the employer did not perform a periodic inspection of the energy control program to identify problems or training issues thereby exposing employees to a contact hazard.
Recent events (3)
- — F (S) $600
- — C (S) $1200
- — Z (S) $1200
1910.147 C07 I A
- Issued
- Mar 6, 2015
- Abate by
- Jul 17, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a. At the machine shop were employees performed servicing and maintenance on machines such as the shear and HTC press brake, the employees were not provided Lock-out/Tag-out training on the proper procedures for ensuring the equipment was at zero energy.
Recent events (3)
- — F (S) $1000
- — C (S) $2000
- — Z (S) $2000
1910.157 G02
- Issued
- Mar 6, 2015
- Abate by
- Apr 10, 2015
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The employer shall provide the education required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter. a. In the machine shop where employees performed duties such as operating shears, press brakes and other machinery, the employer did not provide annual fire extinguisher training to employees who would attempt to put out an incipient stage fire thereby exposing employees to a fire/explosion hazard.
Recent events (3)
- — F (S) $0
- — C (S) $1200
- — Z (S) $1200
1910.178 L04 III
- Issued
- Mar 6, 2015
- Abate by
- Sep 17, 2015
- Penalty
- Initial $1,700 · Current $850 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years. a. In the plant where a Komatsu powered industrial truck was used to move materials around the machine shop, the employer did not provide refresher training for safe operation of the powered industrial truck every three years thereby exposing employees to a struck-by hazard.
Recent events (3)
- — F (S) $850
- — C (S) $1700
- — Z (S) $1700
1910.212 A01
- Issued
- Mar 6, 2015
- Abate by
- Jul 17, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a. In the machine shop where employees used a 200 Ton HTC Press Brake, the employer did not provide guarding to protect employees thereby exposing employees to a caught-in hazard.
Recent events (3)
- — F (S) $1400
- — C (S) $2800
- — Z (S) $2800
1910.303 B02
- Issued
- Mar 6, 2015
- Abate by
- Jul 17, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. a. In the machine shop, the energized circuit breaker panel box was not listed or labeled equipment suitable for the housing of exposed live wires used to turn the lights on and off thereby exposing employees to a contact hazard.
Recent events (3)
- — F (S) $1400
- — C (S) $2800
- — Z (S) $2800
1910.303 B07 IV
- Issued
- Mar 6, 2015
- Abate by
- Jul 17, 2015
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. a. In the machine shop, the energized electrical box for the lights was corroded and rusted at the bottom of the electrical box exposing energized wires thereby exposing employees to a contact hazard.
Recent events (3)
- — F (S) $0
- — C (S) $1600
- — Z (S) $1600
1910.303 E01
- Issued
- Mar 6, 2015
- Abate by
- Jul 17, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(e)(1): Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment: 29 CFR 1910.303(e)(1)(ii): Other markings giving voltage, current, wattage, or other ratings as necessary. a. In the machine shop, the electrical circuit breaker panel was not marked with the proper identification to inform employees of the potential electrical hazard thereby exposing employees to a contact hazard.
Recent events (3)
- — F (S) $0
- — C (S) $2000
- — Z (S) $2000
1910.305 B01 II
- Issued
- Mar 6, 2015
- Abate by
- Jul 17, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a. In the machine shop, the electrical disconnect to the brake press had a unused openings in the bottom of the disconnect thereby exposing employees to a contact hazard. b. In the machine shop, there was an unused opening in the bottom of the Shear disconnect thereby exposing employees to a contact hazard. c. In the machine shop, the main disconnect which was not marked had unused openings in the energized disconnect in the bottom and side of the disconnect. d. In the machine shop, the disconnect for the furnace had unused openings where circuit breakers were suppose to be in place thereby exposing employees to a contact hazard. e. In the machine shop, the disconnect for the welder had unused openings to energized electrical thereby exposing employees to a contact hazard. f. In the 550 area for storage and maintenance the Siemans disconnect had unused openings in the side of the energized disconnect thereby exposing employees to a contact hazard. g. In the 550 area for storage and maintenance, the Square D disconnect had an unused opening in the bottom of the disconnect thereby exposing employees to a contact hazard.
Recent events (3)
- — F (S) $1000
- — C (S) $2000
- — Z (S) $2000
1910.305 D02
- Issued
- Mar 6, 2015
- Abate by
- Jul 17, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. a. In the machine shop on the main electrical wall, the employer installed a piece of steel across the front of the energized electrical circuit box and did provide a dead front to keep employees from coming into contact with live circuits thereby exposing employees to a contact hazard.
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1910.1200 H01
- Issued
- Mar 6, 2015
- Abate by
- Apr 10, 2015
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets. a. In the plant where chemicals such as propane, gasoline and other chemicals were used during the performance of their jobs, the employer did not provide Hazard Communication training to employees thereby exposing employees to a contact hazard.
Recent events (3)
- — F (S) $0
- — C (S) $1200
- — Z (S) $1200
More inspections at Mcguire INC.
View Mcguire INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340178953.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.