OSHA Inspection: ALL FENCE DESIGN

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ALL FENCE DESIGN in PARKS RFTA DINING FACILITY DAVIS AVENUE, CAMP PARKS, DUBLIN, CA 94568 (NAICS 238990). OSHA activity number 340179522.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL Fence Design — free Get an email when a new federal OSHA severe-injury report for ALL Fence Design is published. One employer, no account, unsubscribe in one click.
Establishment
ALL FENCE DESIGN
Site address
PARKS RFTA DINING FACILITY DAVIS AVENUE, CAMP PARKS
City
DUBLIN
State
CA
ZIP
94568
Mailing
12260 NEW AIRPORT ROAD, AUBURN, CA 95603
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
2
Ownership type
A

1 citation on file for this inspection.

1926.404 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Jan 27, 2015
Abate by
Feb 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which were not a part of the permanent wiring of the building or structure and which were in use by employees, did not have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator were insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters:  At the east side of the project: There was no assured equipment grounding conductor program and the ground fault circuit interrupter would not trip when the test buttons were pushed on a MQ Multiquip GDP-5H 60/180 High Cycle vehicle mounted generator that powered a 110 VAC concrete mixer to mix Portland cement, exposing employees that used the mixer to the hazard of electric shock.