Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LAKE REGION MEDICAL

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LAKE REGION MEDICAL in 140 E. HINTZ ROAD, WHEELING, IL 60090 (NAICS 339112). OSHA activity number 340180454.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lake Region Medical — free Get an email when a new federal OSHA severe-injury report for Lake Region Medical is published. One employer, no account, unsubscribe in one click.
Establishment
LAKE REGION MEDICAL
Site address
140 E. HINTZ ROAD
City
WHEELING
State
IL
ZIP
60090
Mailing
140 E. HINTZ ROAD, WHEELING, IL 60090
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339112
Employees
350
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 350 exposed
Issued
Apr 22, 2015
Abate by
Jun 9, 2015
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) Department 15, Cell 1106 - The employer had not fully implemented the Hazardous Energy Control Program in that employees performing set-up operations were not utilizing Lockout/Tagout while setting-up machines and equipment, including the Kitamura MyCenter - Zero vertical milling machine, the laser welding machines and EDM machines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1910.147 D

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
Jun 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  (a) Department 15, Cell 1106 - Employees engaged in setting up machines and equipment did not affix a Lockout/Tagout device to the machine prior to performing work on machines and equipment, including the Kitamura MyCenter - Zero vertical milling machine, the laser welders and the EDM machines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I A

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
Jun 9, 2015
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  (a) Department 15, Cell 1106 - Employees performing set-up duties were not trained at the "Authorized" level to perform Lockout/Tagout during set-up.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1910.212 A03 II

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 22, 2015
Abate by
Jul 20, 2015
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:    (a)  Department 15, Cell 1106 - On or about January 7, 2015, the enclosure door to the Kitamuara MyCenter-ZERO, Machine ID #XNN40, CNC machining center, was not provided with an electrical interlock to prevent the operator from opening the door during production operations and reaching into the point of operation.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5000

1910.147 C01

Other-than-serious 5 instances 3 exposed
Issued
Apr 22, 2015
Abate by
Jun 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  (a) The hazardous energy control program (Lockout/Tagout) did not address the following information:    (1) Training of "other" employees;    (2) Temporary removal of Lockout/Tagout devices for testing or positioning of machines;    (3) Sharing of the Lockout/Tagout program with outside personnel (contractors);    (4) Group Lockout/Tagout; and    (5) Shift or personnel changes.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Lake Region Medical's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340180454.