Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCESS LIFT EQUIPMENT, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ACCESS LIFT EQUIPMENT, INC. in 2180 CARBAUGH AVENUE, CHAMBERSBURG, PA 17201 (NAICS 333120). OSHA activity number 340181486.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Access Lift Equipment, INC. — free Get an email when a new federal OSHA severe-injury report for Access Lift Equipment, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2180 CARBAUGH AVENUE
City
CHAMBERSBURG
State
PA
ZIP
17201
Mailing
2180 CARBAUGH AVENUE, CHAMBERSBURG, PA 17201
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333120
Employees
8
Ownership type
A

9 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 22, 2015
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  (a) SHOP - MEZZANINE AREA FOR THE PARTS ROOM, BREAK ROOM, RESTROOM, FOREMAN OFFICE  - Employees worked from the mezzanine area above the shop support rooms where standard railings and toe board are not provided, thereby exposing the employees to a fall hazard of approximately twelve (12) feet to the ground below, on or about January 14, 2015.   (b) SHOP - MEZZANINE AREA FOR THE MECHANICAL ROOM - Employees worked from the mezzanine area above the shop air compressor and heat supply room where standard railings and toe board are not provided, thereby exposing the employees to a fall hazard of approximately twelve (12) feet to the ground below, on or about January 14, 2015.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.67 C02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 18, 2015
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.67(c)(2)(ii): Only trained persons shall operate an aerial lift.   (a) FACILITY WIDE - Employees operated various aerial lifts (i.e Genie S125, JLG 400S) throughout the facility on a daily basis for maintenance, repair and diagnostic purposes. The employer did not ensure that employees had successfully completed an aerial lift training program prior to permitting an employee to operate an aerial lift on or about January 14, 2015  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.67 C02 V

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
May 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.67(c)(2)(v): A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift:  a) FACILITY WIDE - Employees did not wear body harnesses with lanyard attachment when they operated various aerial lifts throughout the facility for maintenance, repair and diagnostic purposes on or about January 14, 2015  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G02

Serious Gravity 1 1 instance 8 exposed
Issued
Apr 22, 2015
Abate by
May 18, 2015
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:  a) Access Lift Equipment, Inc. - The employer did not communicate employees to evacuate the building in case of a fire nor train employees upon initial hire and at least annually thereafter on the use of portable fire extinguishers and the hazards involved with incipient stage fire fighting on or about January 14, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $900
  • — Z (S) $1200

1910.178 M02

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2015
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.178(m)(2): Employee(s) stood under or passed under the elevated portion of a powered industrial truck(s)  a)  In the Shop - On or about January 14, 2015, an employee, performed diagnostic and repair work on the ground control box of the JLG Model 1930ES Scissor Lift while it was elevated approximately 4 feet off the floor by the forks of the Komatsu Model 30 forklift. The employees hands and legs were observed under the elevated load during this repair activity.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1910.178 M05 III

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(m)(5)(iii): Powered industrial truck(s), with the operator dismounted and within 25 feet of the truck still in his view, did not have the load engaging means fully lowered:    a)  In the Shop - On or about January 14, 2015, an employee, performed diagnostic and repair work on a JLG Model 1930ES Scissor Lift while it was elevated approximately 4 feet off the floor by the forks of the Komatsu Model 30 forklift.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 B02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2015
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    a)  In the Shop - On or about January 14, 2015, employees, working in the shop, were exposed to welding arc flashes and ultraviolet radiation because welding shields or screens were not used to protect the employees from nearby arc welding repairs.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1910.22 D01

Other-than-serious 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
May 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  (a)  TOP OF EMPLOYEE PARTS ROOM, BREAK ROOM, RESTROOM, FOREMAN OFFICE - The roof of the employee restroom, break room, foreman office was used for storage purposes, and the structure was not marked for approved loads, on or about January 14, 2015.  (b)  TOP OF MECHANICAL ROOM - The roof of the compressor room and heater supply room was used for storage purposes, and the structure was not marked for approved loads, on or about January 14, 2015.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 3 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)  NORTHEAST MAIN SHOP - The employer did not ensure that the space in front of the main electrical panel on the Northeast wall adjacent to the man door entrance permitted ready and safe access to the panel, in that access to the panels was hindered by fuel containers, package deliveries and a charging station, thereby exposing employees to possible injuries, on or about January 14, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Access Lift Equipment, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340181486.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.