On , OSHA opened a referral safety inspection of DAP CONSTRUCTION, INC. in 10 ALLEN ST, ALLENHURST, NJ 07711 (NAICS 238130). OSHA activity number 340181536.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DAP Construction, INC. — free Get an email when a new federal OSHA severe-injury report for DAP Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10 ALLEN ST
City
ALLENHURST
State
NJ
ZIP
07711
Mailing
272 DUNNS MILL ROAD BOX 256, BORDENTOWN, NJ 08505
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 9, 2015
Abate by
Jul 6, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.20(b)(2): The employer did not develop an accident prevention program, that provided for frequent and regular inspections of the job sites, materials, and equipment, to be made by competent persons designated by the employer.  a)10 Allen St, Allenhurst, NJ (Front of First Floor Framing): Employer did not initiate frequent and regular inspections by a competent person of the jobsite and equipment which were found to have safety hazards on or about 12/22/14.  NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2000

1926.403 D01

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 9, 2015
Abate by
Jul 6, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted:  a)10 Allen St, Allenhurst, NJ (Front of Framing Structure): Emplooyees were using a flexible cable which was reun to a permanent fixture metal 2 outlet junction box which was not mounted on or about 12/22/14.   NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2800

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 9, 2015
Abate by
Jul 6, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system.  a)10 Allen St, Allenhurst, NJ (Top of First Floor Framing): Employees were walking the top plate of the first floor framing of a residential property without any means of fall protection on or about 12/22/14.  NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $2000

1926.1053 B13

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 9, 2015
Abate by
Jul 6, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a)10 Allen St, Allenhurst, NJ (Front of Framing Structure): Employees were working on a fiberglass "A"- Frame ladder to place framing pieces and nail them on or about 12/22/14.  NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $1200

1926.1053 B16

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 9, 2015
Abate by
Jul 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.  a)10 Allen St, Allenhurst, NJ (Front of Framing Structure): Employees were working on an A Frame ladder which had visible defects to nail part of the framing structure on or about 12/22/14.   NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.