OSHA Inspection: GATOR FABRICATION LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GATOR FABRICATION LLC in 101 E AVENUE M, CONROE, TX 77301 (NAICS 237120). OSHA activity number 340182674.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gator Fabrication LLC — free Get an email when a new federal OSHA severe-injury report for Gator Fabrication LLC is published. One employer, no account, unsubscribe in one click.
Site address
101 E AVENUE M
City
CONROE
State
TX
ZIP
77301
Mailing
PO BOX 2988, CONROE, TX 77301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.101 B

Serious Gravity 5 5 instances 22 exposed
Issued
Mar 25, 2015
Abate by
Apr 4, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.101(b): Section 3.4.4, Compressed Gas Association Pamphlet P11965, as adopted by 29 CFR 1910.101(b): Before using cylinder, be sure it is properly supported to prevent it from being knocked over.  The employer does not ensure that before using cylinders that they are supported to prevent them from being knocked over.  This violation was observed on or about January 15, 2015 in the main fabrication shop where employees were exposed to struck-by hazards due to cylinders not being secured from falling over prior to use.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that cylinders are secured against being knocked over prior to use.
Recent events (1)
  • — Z (S) $2800

1910.253 B04 III

Serious Gravity 5 1 instance 30 exposed
Issued
Mar 25, 2015
Penalty
Initial $2,380 · Current $2,380
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  The employer does not ensure that oxygen cylinders in storage were separated from fuel-gas cylinders or combustible materials by a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet high (1.5 m) having a fire resistance rating of at least one-half hour.  This violation was observed on or about March 11, 2015, near the north-west exterior corner of the main fabrication shop where employees were exposed to fire and explosion hazards where an oxygen cylinder was stored near fuel-gas cylinders.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that oxygen cylinders in storage are separated from fuel-gas cylinders or combustible materials by a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet high (1.5 m) having a fire resistance rating of at least one-half hour.
Recent events (1)
  • — Z (S) $2380

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 25, 2015
Penalty
Initial $2,380 · Current $2,380
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws  The employer does not ensure that flexible cords and cables were connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws. This violation was observed on or about January 15, 2015, in the main fabrication shop where employees were exposed to electrical hazards when using a portable grinder whose cord was spliced with no strain relief.  Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that flexible cords and cables were connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.
Recent events (1)
  • — Z (S) $2380