CONYERS, GA —
OSHA Inspection: ACTION METAL FABRICATORS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ACTION METAL FABRICATORS, INC. in 1951 OLD COVINGTON RD NE, CONYERS, GA 30012 (NAICS 332999). OSHA activity number 340183235.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACTION METAL FABRICATORS, INC.
- Site address
- 1951 OLD COVINGTON RD NE
- City
- CONYERS
- State
- GA
- ZIP
- 30012
- Mailing
- PO BOX 228, CONYERS, GA 30012
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 21
- Ownership type
- A
Citations
18 citations on file for this inspection.
1910.106 D03 II A
- Issued
- Jun 30, 2015
- Abate by
- Aug 27, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(a): Metal cabinets were not deemed to be in compliance as they were not constructed with the bottom, top, door, and sides of cabinet at least No. 18 gage sheet iron and double walled with 1 1/2-inch air space; the joints riveted, welded, or made tight by some equally effective means; the door provided with a three-point lock; and/or the door sill raised at least 2 inches above the bottom of the cabinet: On or about January 15, 2015: Employees working in and around the flammable storage area are exposed to fire and explosion hazards, where chemicals such as but not limited to liquid paints, aerosol paints, lacquers, and lacquer thinner are stored in two cabinets. a. The small storage cabinet was not constructed of at least 18 gage steel, was not double walled, and did not have a raised door sill of at 2 inches to contain spills. b. The large storage cabinet was not constructed of at least 18 gage steel, was not double walled, and did not have a three-point locking mechanism.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.106 D03 II
- Issued
- Jun 30, 2015
- Abate by
- Aug 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(3)(ii): Flammable liquid storage cabinet(s) were not labeled in conspicuous lettering, "Flammable - Keep Fire Away": On or about January 15, 2015: Employees working in and around the flammable storage area are exposed to fire and explosion hazards, where chemicals such as but not limited to paints, aerosol paints, lacquers, and lacquer thinner are stored in two cabinets. The cabinets are not marked with lettering stating "Flammable-Keep Fire Away".
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about January 15, 2015: The spray painter is require to wear a 3M half face respirator. The employer had not established and implemented a written respiratory protection program.
Recent events (2)
- — I (S) $2400
- — Z (S) $2400
1910.134 E01
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about January 15, 2015: The painter is required to wear a 3M Half Face Respirator when painting. The employer did not provide the painter with a medical evaluation prior to the required use of the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: On or about January 15, 2015: The painter is required to wear a 3M Half Face Respirator when painting. The employer had not provided respirator fit testing for the painter.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Jun 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: On or about January 15, 2015: During the inspection the painters 3M Half Face Respirator was hanging on a nail in the paint storage area exposing him to possible inhalation and contact/skin contamination. The employer did not ensure that employees are storing respirators properly.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about January 15, 2015: Employees operating the Ermaksan Power Bend Falcon 12.3 Press Brake located in the press brake area are exposed to amputation hazards. The employer did not have lock out / tag out procedures for this piece of equipment. Machine #19092-P2J3J6, 286 ton capacity, 230/460 volts.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.147 C05 II B
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(B): Lockout and tagout devices were not standardized within the facility in at least one of the following criteria: color; shape; or size: On or about January 15, 2015: The employer was using different size and shaped locks as well as different color locks for their lock out tag out program. The locks were not standardized.
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1910.215 A04
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: On or about January 15, 2015: Employees working in the machine shop and using the Jet Electric Bench Grinder for smoothing or to deburr small parts are exposed to struck by hazards. The work rests were not adjusted to one eighth inch from the wheel.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1910.215 B09
- Issued
- Jun 30, 2015
- Abate by
- Aug 27, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: On or about January 15, 2015: Employees working in the machine shop and using the Jet Electric Bench Grinder for smoothing or to deburr small parts are exposed to struck by hazards. The tongue guards were missing or the distance between the abrasive wheel and the tongue guards exceeded one fourth inch.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.242 B
- Issued
- Jun 30, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about January 15, 2015: Employees working in the machine shop area were exposed to struck by hazards from flying metal pieces when using the compressed air to clean fine metal debris from the equipment. The compressed air used at the milling machine was at 65 p.s.i.
Recent events (2)
- — I (O) $0
- — Z (S) $2000
1910.253 B02 II
- Issued
- Jun 30, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: On or about January 15, 2015: Employees working on the production floor were expose to struck by hazards where cylinders of propane and acetylene located near the bay were subject to being knocked over.
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
1910.303 G01 II
- Issued
- Jun 30, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: On or about January 15, 2015: Employees working in the facility were exposed to trip hazards from items and debris stored in front of and around the electrical panel boxes in the following areas: a) Panel boxes between the forming area and laser table area b) Panel box in the machine shop c) Panel box in the shear and laser table area
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
1910.305 B01 II
- Issued
- Jun 30, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about January 15, 2015: Employees working in the facility are exposed to electrical shock hazards where openings in the electrical panel boxes near the press area were not covered.
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
1910.305 G01 IV A
- Issued
- Jun 30, 2015
- Abate by
- Aug 27, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: On or about January 15, 2015: Employees working in the machine shop are exposed to electrical hazards where the employer used flexible cords for lighting fixtures in lieu of fixed wiring.
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1910.1200 E01
- Issued
- Jun 30, 2015
- Abate by
- Aug 27, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about January 15, 2015: Employees working in the production area of the facility are exposed to flammable and combustible chemicals such as, but not limited to Sunnyside Lacquer Thinner, Polane Plus Sealer (Gray), Rustlick Synthetic Machining Coolant and Rust-oleum Industrial High Heat Coatings. The employer had not established a written hazard communication program.
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1910.1200 E01 I
- Issued
- Jun 30, 2015
- Abate by
- Aug 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. On or about January 15, 2015: Employees working in the production area of the facility are exposed to flammable and combustible chemicals such as, but not limited to Sunnyside Lacquer Thinner, Polane Plus Sealer (Gray), Rustlick Synthetic Machining Coolant and Rust-oleum Industrial High Heat Coatings. The employer did not have an inventoried list of chemicals used in the worksite.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Jun 30, 2015
- Abate by
- Aug 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about January 15, 2015: Employees working in the production area of the facility are exposed to flammable and combustible chemicals such as, but not limited to Sunnyside Lacquer Thinner, Polane Plus Sealer (Gray), Rustlick Synthetic Machining Coolant and Rust-oleum Industrial High Heat Coatings. The employer did not provide hazardous chemical training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Action Metal Fabricators, INC.
View Action Metal Fabricators, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340183235.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.