Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GRAVLEY DOOR COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GRAVLEY DOOR COMPANY in 14565 INDUSTRIAL PARKWAY, AUBREY, TX 76227 (NAICS 321911). OSHA activity number 340183763.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gravley Door Company — free Get an email when a new federal OSHA severe-injury report for Gravley Door Company is published. One employer, no account, unsubscribe in one click.
Site address
14565 INDUSTRIAL PARKWAY
City
AUBREY
State
TX
ZIP
76227
Mailing
PO BOX 560, AUBREY, TX 76227
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
40
Ownership type
A

8 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 35 exposed
Issued
Jun 23, 2015
Abate by
Jul 22, 2015
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:    In the south end of the production shop, a flexible cord that was used to connect a portable hand sander to the electrical source was hanging down and lying across the walk area, exposing employees to tripping hazards.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.213 A09

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 23, 2015
Abate by
Jul 22, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219:    In the northeast section of the production shop, employees operated an Extrema double-sided planer that had an unguarded belt and two pulleys at the bottom of the machine, exposing employees to being caught in the in-running nip points.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.213 H01

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 23, 2015
Abate by
Jul 22, 2015
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the maximum protection possible for the operation being cut.    In the southeast section of the production area, the De Walt radial arm saw did not have a self-adjusting blade guard, exposing employees to hazards of amputations, lacerations, and/or broken bones.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.213 H02

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 23, 2015
Abate by
Jul 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.213(h)(2): Radial saw(s) used for ripping were not provided with nonkickback fingers or dogs located on both sides of the saw so as to oppose the trust or tendency of the saw to pick up material or throw it back toward the operator:  In the southeast area of the production department, the De Walt radial arm saw did not have an anti-kickback device attached, exposing employees to hazards of amputations, broken bones, and/or lacerations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 10 2 instances 10 exposed
Issued
Jun 23, 2015
Abate by
Jul 22, 2015
Penalty
Initial $4,900 · Current $2,450 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    (a)  Near the south end of the production area, near the downdraft table, a gangway outlet box that was used to connect a sander to the power source was suspended from the rafters and was not mounted and used as designed by the manufacturer, exposing employees to electrical shock and fire hazards.    (b)  Near the center of the production area, an outlet box that was near the clamp machine was tied to the machine by the flexible cord, not mounted and not used as designed by the manufacturer, exposing employees to electrical shock and fire hazards.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $4900

1910.303 G01

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 23, 2015
Abate by
Jul 22, 2015
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    On the west side of the production area, access to the electrical panel boxes to disengage the power in an emergency was blocked by a table which was bolted to the floor, exposing employees to electrical shock and fire hazards.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.305 B01 II

Deleted Serious Gravity 10 2 instances 5 exposed
Issued
Jun 23, 2015
Abate by
Jul 22, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a)  On the north wall of the production area, an outlet box used to supply power for the Lobo boring machine had a opening that was not effectively closed, exposing employees to electrical and fire hazards.  (b)  Near the southwest corner of the production area, the electrical panel box had unused openings that were not covered, exposing employees electrical and fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.305 G02 III

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Jun 23, 2015
Abate by
Jul 22, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    At the northeast portion of the production area, the flexible power cord connecting the Rockwell radial arm saw to the power source did not have a strain relief device and the outer sheathing was torn, pulled back with the internal wires showing, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

View Gravley Door Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340183763.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.