MANVEL, TX —
OSHA Inspection: APACHE PRESSURE PRODUCTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of APACHE PRESSURE PRODUCTS in 3909 BAILEY RD., MANVEL, TX 77578 (NAICS 423840). OSHA activity number 340183938.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APACHE PRESSURE PRODUCTS
- Site address
- 3909 BAILEY RD.
- City
- MANVEL
- State
- TX
- ZIP
- 77578
- Mailing
- 3909 BAILEY RD., MANVEL, TX 77578
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423840
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 L01 I
- Issued
- Mar 6, 2015
- Abate by
- Mar 25, 2015
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) In the warehouse employees permitted to operate the Mitsubishi fork lift, model number FGC25N1, serial number AF82F10348, had not received training.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
1910.178 L06
- Issued
- Mar 6, 2015
- Abate by
- Mar 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by paragraph (l) through a certification that included the name of the operator, the date of the training, that date of evaluation, and the identity of the person(s) performing the training or evaluation: a) In the warehouse the employer did not maintain a certification of the training of operators of the forklifts. Attendance list and training matrix were requested and nothing was provided by the employer.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 E03
- Issued
- Mar 6, 2015
- Abate by
- Mar 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): The date of the annual maintenance check of portable fire extinguishers was not recorded: a) On the fork lift the portable fire extinguisher did not have the tag showing that the annual inspection was done.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 423840)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340183938.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.