GILFORD, NH —
OSHA Inspection: US HOME IMPROVEMENT, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of US HOME IMPROVEMENT, LLC in 81 ELM STREET, GILFORD, NH 03249 (NAICS 238160). OSHA activity number 340184944.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- US HOME IMPROVEMENT, LLC
- Site address
- 81 ELM STREET
- City
- GILFORD
- State
- NH
- ZIP
- 03249
- Mailing
- 11 HAWKINS STREET, SOMERVILLE, MA 02143
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Jan 26, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) Location: site On or about 1/16/15, employees were not protected from head injury while working under roofing operations without head protection.
Recent events (1)
- — Z (S) $2000
1926.502 D15
- Issued
- Jan 26, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person. (a) location: site On or about 1/16/15 employees were not adequately protected from falling while utilizing a 5,000 lb. rated personal fall arrest anchor with two employees connected to it.
Recent events (1)
- — Z (S) $2000
1926.502 D17
- Issued
- Jan 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: (a) Location: on the roof On or about 1/16/15, the employer did not ensure employees using body harnesses had the lanyards attached in the center of the wearer's back near shoulder level.
Recent events (1)
- — Z (S) $0
More inspections at US Home Improvement, LLC