WASHINGTON, DC —
OSHA Inspection: MPC CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MPC CONSTRUCTION in 4411 12TH. ST., NE, WASHINGTON, DC 20017 (NAICS 236118). OSHA activity number 340190131.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MPC CONSTRUCTION
- Site address
- 4411 12TH. ST., NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20017
- Mailing
- 131 COLFAX DR., MANASSAS, VA 20111
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.403 D01
- Issued
- Feb 20, 2015
- Abate by
- Mar 12, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted: a) SW Corner of House, Electrical Service Entrance On or about 01/16/2015, construction workers were exposed to an electrical contact hazard from an electrical meter and associated cables which were not attached to the side of a house as they are intended to be. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2000
1926.405 B02
- Issued
- Feb 20, 2015
- Abate by
- Mar 12, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) All Floors - On or about 01/16/2015, construction workers were exposed to a 120 volt electrical contact hazard from wall-mounted outlet and switch boxes which were not provided with covers. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2800
1926.405 D
- Issued
- Feb 20, 2015
- Abate by
- Mar 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front: a) Basement On or about 01/16/2015, construction workers were exposed to a 120 volt electrical contact hazard from a circuit distribution panel which was not provided with a cover and had no dead front. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1926.1052 B03
- Issued
- Feb 20, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1052(b)(3): Treads for temporary stairway service were not installed the full width and/or depth of the stair: a) Front Entrance Stairs - On or about 01/16/2015, construction workers were exposed to a fall hazard while using a set of stairs which had not been provided with stair treads while they accessed the main entrance of a house.
Recent events (1)
- — Z (S) $1200
1926.1052 C01 I
- Issued
- Feb 20, 2015
- Abate by
- Mar 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Basement Stairs On or about 01/16/2015, construction workers using a set of stairs to access a houses basement were exposed to up to a 10 foot fall and were not provided with a handrail. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1926.1052 C01 II
- Issued
- Feb 20, 2015
- Abate by
- Mar 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): A set of stairs was not provided at least one stairrail system along each unprotected side or edge: a) Front Entrance Stairs - On or about 01/16/2015, construction workers using a set of stairs having five risers to access the front entrance to a house were not provided with stairrails on either of the stairs open sides. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1926.1053 B12
- Issued
- Feb 20, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails: a) SW Corner of House On or about 01/16/2015, a carpenter was installing wood trim from an aluminum ladder which was located approximately 3 feet from a live overhead power line.
Recent events (1)
- — Z (S) $2000
More inspections at MPC Construction
View MPC Construction's full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340190131.