Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HALLIBURTON ENERGY SERVICES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HALLIBURTON ENERGY SERVICES in 101 HOLT RD, VICTORIA, TX 77905 (NAICS 327310). OSHA activity number 340191683.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Halliburton Energy Services — free Get an email when a new federal OSHA severe-injury report for Halliburton Energy Services is published. One employer, no account, unsubscribe in one click.
Site address
101 HOLT RD
City
VICTORIA
State
TX
ZIP
77905
Mailing
101 HOLT RD, VICTORIA, TX 77905
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327310
Employees
100000
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Other-than-serious 1 instance 1 exposed
Issued
Jun 2, 2015
Abate by
Jun 26, 2015
Penalty
Initial $5,610 · Current $4,000 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    At this cement processing plant, at the bulk sampling area, the employers written procedures for LOTO when performing maintenance and servicing the Sentry Sampler Model RX were not utilized.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $5610

1910.147 C06 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jun 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  At this cement processing plant, the employer did not certify that periodic inspections of the hazardous energy control program had been completed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Halliburton Energy Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340191683.