VICTORIA, TX —
OSHA Inspection: HALLIBURTON ENERGY SERVICES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HALLIBURTON ENERGY SERVICES in 101 HOLT RD, VICTORIA, TX 77905 (NAICS 327310). OSHA activity number 340191683.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HALLIBURTON ENERGY SERVICES
- Site address
- 101 HOLT RD
- City
- VICTORIA
- State
- TX
- ZIP
- 77905
- Mailing
- 101 HOLT RD, VICTORIA, TX 77905
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327310
- Employees
- 100000
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jun 2, 2015
- Abate by
- Jun 26, 2015
- Penalty
- Initial $5,610 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: At this cement processing plant, at the bulk sampling area, the employers written procedures for LOTO when performing maintenance and servicing the Sentry Sampler Model RX were not utilized.
Recent events (2)
- — I (O) $4000
- — Z (S) $5610
1910.147 C06 II
- Issued
- Jun 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: At this cement processing plant, the employer did not certify that periodic inspections of the hazardous energy control program had been completed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Halliburton Energy Services