LINDEN, NJ —
OSHA Inspection: LUXOR LINENS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LUXOR LINENS, LLC in 1416 E. LINDEN AVE. SUITE C, LINDEN, NJ 07036 (NAICS 812331). OSHA activity number 340192129.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LUXOR LINENS, LLC
- Site address
- 1416 E. LINDEN AVE. SUITE C
- City
- LINDEN
- State
- NJ
- ZIP
- 07036
- Mailing
- 1418 E. LINDEN AVE. SUITE A, LINDEN, NJ 07036
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812331
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 C01
- Issued
- Feb 12, 2015
- Abate by
- Mar 3, 2015
- Penalty
- Initial $1,700 · Current $1,105 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides of platform: a/ Luxor/Linden NJ Site: Warehouse Suite C. Linen Sheets Area: An employee was observed standing on the open-side of a stack of cardboard boxes filled with product, while attempting to retrieve a box of product that was located approx. 8 ft from the floor. Means were not provided to prevent employee(s) from standing on unapproved platforms to store and/or retrieve product. Observed on/or about 01/20/2015.
Recent events (2)
- — I (S) $1105
- — Z (S) $1700
1910.36 D01
- Issued
- Feb 12, 2015
- Abate by
- Mar 3, 2015
- Penalty
- Initial $1,700 · Current $1,105 Reduced
General-duty citation text
29 CFR 1910.36(d)(1): Exits were locked or fastened preventing free escape from inside of the building: a/ Luxor/Linden NJ Site: Warehouse Suite C. Street Side: Exit door leading to the street facing another facility was locked with a sliding bolt preventing immediate escape in the event of a fire or other emergency. Observed on/or about 01/20/2015.
Recent events (2)
- — I (S) $1105
- — Z (S) $1700
1910.36 G02
- Issued
- Feb 12, 2015
- Abate by
- Mar 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(2): The exit access was not at least 28 inches wide (71.1 cm) wide at all points: a) Luxor/Linden NJ Site: Warehouse Suite C. Linen Sheets and Pillow Areas: Employee work stations were not provided with a minimum of 28 inches of walking space where only 12 to 16 inches of space were estimated to be maintained. The work station aisles were partially blocked by empty cardboard boxes and partially filled boxes of product. Observed on/or about 01/20/2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01 II
- Issued
- Feb 12, 2015
- Abate by
- Mar 3, 2015
- Penalty
- Initial $1,020 · Current $670 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space provided about electrical equipment rated 600 volts, nominal, or less was used for storage:. a/ Luxor/Linden NJ Site: Warehouse Suite C. Shipping/Receiving Dock: Electrical panel boxes (voltage 480 Volts/3 phase) were not maintained free of storage material, e.g., boxes of fluorescent light bulbs, U-Line Products and a small portable fan. A minimum 30 inches of space was not maintained in front of the electrical panels. Observed on/or about 01/20/2015.
Recent events (2)
- — I (S) $670
- — Z (S) $1020
1910.157 C01
- Issued
- Feb 12, 2015
- Abate by
- Mar 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a/ Luxor/Linden NJ Site: Warehouse Suite C. Linen Pillow Area: Portable fire extinguisher was not maintained free of cardboard boxes of storage and loose pillows. Observed on/or about 01/20/2015.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 812331)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340192129.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.