Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COMMERCIAL WAREHOUSING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COMMERCIAL WAREHOUSING, INC. in 102 INDUSTRIAL BLVD, WINTER HAVEN, FL 33880 (NAICS 493120). OSHA activity number 340194489.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Commercial Warehousing, INC. — free Get an email when a new federal OSHA severe-injury report for Commercial Warehousing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
102 INDUSTRIAL BLVD
City
WINTER HAVEN
State
FL
ZIP
33880
Mailing
100 INDUSTRIAL BLVD., WINTER HAVEN, FL 33880
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
62
Ownership type
A

15 citations on file for this inspection.

1910.36 G02

Serious Gravity 5 1 instance 30 exposed
Issued
Jul 10, 2015
Abate by
Nov 16, 2015
Penalty
Initial $3,600 · Current $2,880 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.    a) For the Commercial Warehousing T5/T6 ammonia refrigeration facility as observed on or about 04/01/2015, exit aisles in the warehouse areas such as freezer #2 were blocked by pallets of material. At multiple locations, it was impossible to fit through/past material staged in aisles resulting in the emergency exit access being blocked.
Recent events (2)
  • — I (S) $2880
  • — Z (S) $3600

1910.119 D03 I B

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 10, 2015
Abate by
Nov 16, 2015
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(d)(3)(i)(B): The employer's piping and instrument diagrams were not accurate and did not represent equipment that was existing and was part of the process:    For the Commercial Warehousing ammonia refrigeration facility located at 101 and 102 Industrial Blvd. in Winter Haven, FL as observed on or about 1/15/2015: The piping and instrumentation diagrams for the ammonia refrigeration process were incomplete and inaccurate in that:    a) Spring-loaded self-closing valves at oil pots were not depicted on the process and instrumentation diagrams.    b) Electrical control schemes for accumulator and intercooler high level control cutoffs were not depicted on the process and instrumentation diagrams.    c) Electrical emergency shutdown systems for T6-north and T6-south engine rooms were not depicted on process and instrumentation diagrams.    d) Piping changes connecting T6-North and T6-South refrigeration systems to T5 refrigeration system were not depicted on process and instrumentation diagrams.    e) Solenoid valve additions and control schemes to control the flow of ammonia between T6-north, T6-south, and T5 ammonia systems/engine rooms were not depicted on process and instrumentation diagrams.    f) T5 engine room equipment was not included in the process and safety instrumentation diagrams.    g) Gauges for measurement of temperature and pressure were not depicted on the process and instrumentation diagrams.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 D03 I D

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 10, 2015
Abate by
Nov 16, 2015
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(d)(3)(i)(D): The employer did not include, in the process safety information compilation, the relief system design and the design basis:    a) For the Commercial Warehousing ammonia refrigeration facility located at 101 and 102 Industrial Blvd. in Winter Haven, FL as observed on or about 1/15/2015: Information on the design basis of the relief system was not available such as, but not limited to, calculations to show that the relief valves' sizing and the relief piping sizing were of a safe design to handle all potential release scenarios.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 D03 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 10, 2015
Abate by
Mar 15, 2016
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices:    For the Commercial Warehousing ammonia refrigeration facility located at 101 and 102 Industrial Blvd. in Winter Haven, FL as observed on or about 1/15/2015:     a) Pressure vessels in the engine rooms such as, but not limited to, the T6-North were operated at temperatures below their minimum design metal temperature.    b) Ammonia detectors were not interlocked to ventilation fans in engine rooms, and ventilation fans in engine rooms did not have an interlocked supervisory alarm that would sound if the ventilation fans shut off.    c) Remote actuation of ventilation system, outside of engine room, was not available. The only way to turn on fans was from a breaker inside the engine rooms.    d) Ammonia relief vent discharge was located at a height of 19-20 ft. above ground and only 9-12 ft. from the T6 north engine room's ventilation intake while the employer's process safety information stated that the relief discharge shall not be within 20 feet of a ventilation intake. This location exposed employees working outside in the area around the high pressure receiver, the condensers, and at the engine room entrance door to potential ammonia concentrations above ammonia's IDLH, 300 ppm. The relief discharge's location also resulted in the potential for ammonia vapors to be pulled back into the engine room from the ventilation intake.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 E05

Serious Gravity 5 6 instances 62 exposed
Issued
Jul 10, 2015
Abate by
Nov 16, 2015
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(e)(5): The employer did not establish a system to promptly address the team's findings and recommendations; assure that the recommendations were resolved in a timely manner with documented resolutions; document the actions that were to be taken; complete actions as soon as possible; develop a written schedule of action completion dates; or communicate the actions to operating maintenance, and other employees working in the process areas or who may have been affected by the recommendations or actions:    For the Commercial Warehousing facility as observed on or about 01/15/2015, PHA action items that had been initiated in 2007 and 2012 were still not resolved. There was no system in place to track these items, no expected completion dates, no designation of who the responsible party was, and no priority ranking. The following action items were still not completed:    a) Single relief valves were not all replaced with dual relief valves - 2007 PHA - Action Item #1    b) Maintenance and calibration of ammonia detectors had not been accomplished - 2007 PHA - Action Item #4    c) Ammonia detectors had not been installed in the warehouse areas - 2007 PHA - Action Item #5    d) Equipment still had single relief valves and a written isolation and change-out procedure had not been established - 2012 PHA - Action Item #2    e) Ammonia detectors had still not been installed and the existing one in T6 engine room north (only detector on site) had not been calibrated. - 2012 PHA -  Action Item #7    f) The employer's emergency action plan (EAP) did not comply with 1910.38 in that there was no alarm system for an ammonia release, no alarm system for a fire that was audible in the freezers, and the EAP did not have procedures to describe how refrigeration employees were to distinguish between a small leak that they could isolate and a larger leak that required evacuation. 2012 PHA -  Action Item #11.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 F01

Serious Gravity 5 5 instances 3 exposed
Issued
Jul 10, 2015
Abate by
Nov 16, 2015
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and addressing at least steps for each operating phase, safe operating limits, safety and health considerations, and safety systems and their functions as outlined by this paragraph:    For the Commercial Warehousing ammonia refrigeration facility located at 101 and 102 Industrial Blvd. in Winter Haven, FL as observed on or about 1/15/2015, complete and clear operating procedures for the following employee process activities were not developed and implemented for using new computerized G-force compressor control panels
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 F03

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 10, 2015
Abate by
Nov 16, 2015
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(f)(3): The employer did not certify that operating procedures were current and accurate:    a) For the Commercial Warehousing facility at 101 and 102 Industrial Blvd., Winter Haven, FL, as observed on or about 01/15/2015, the employer did not annually certify operating procedures for its T5/T6 anhydrous ammonia refrigeration process.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 F04

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 10, 2015
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel:    a) For the Commercial Warehousing ammonia refrigeration facility located at 101 and 102 Industrial Blvd. in Winter Haven, FL as observed on or about 1/15/2015, safe work procedures were not developed for operational activities that resulted in the opening of the ammonia process such as draining/purging of oil.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 I01

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 10, 2015
Abate by
May 16, 2016
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(i)(1): The employer did not perform a pre-startup safety review for new facilities and for modified facilities when the modification was significant enough to require a change in the process safety information.    a) For the Commercial Warehousing ammonia refrigeration facility at 102 and 101 Industrial Blvd. in Winter Haven, FL as observed on or about 1/15/2015, a pre-startup safety review was not conducted when the T5 ammonia refrigeration system had its high pressure receiver removed, condensers taken out of service, and new piping and solenoid valves installed to connect the T5 system to the T6-North and T6-South high pressure receivers.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 L01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 10, 2015
Abate by
May 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.119(l)(1): The employer did not implement procedures to manage changes to process chemicals, technology, equipment, and procedures, and changes to facilities that affect a covered process:    For the Commercial Warehousing ammonia refrigeration facility at 102 and 101 Industrial Blvd. in Winter Haven, FL as observed on or about 1/15/2015, management of change procedures were not implemented for the following technological and equipment changes that were conducted on the system:    a) Changes were made to compressor control panels in that replacement/upgrading of the Mycom compressor control panels with G-force panels started in 2012 and is being continued to present day.    b) In 2012, the T5 engine room was connected to the T6 north and south engine rooms. This resulted in the eliminating of the T5 receiver, compressor, and their associated valves and piping in T5 engine room. It also involved the installation of piping and valves connecting T6 north and south process piping to T5 process piping and pressure vessels and the addition of solenoid valves to control the distribution of ammonia between engine rooms.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 J02

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 10, 2015
Abate by
Nov 16, 2015
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(j)(2): The employer did not implement written procedures to maintain the on-going integrity of process equipment:    For the Commercial Warehousing ammonia refrigeration facility located at 101 and 102 Industrial Blvd. in Winter Haven, FL as observed on or about 1/15/2015: preventative maintenance/mechanical integrity procedures were not implemented, in that, equipment was not serviced on a programmed basis as established by PM/mechanical integrity procedures; rather, equipment was serviced as needed when it failed. Equipment such as, but not limited to, the following were not inspected or serviced in accordance with the employer's mechanical integrity program:    a) Compressors oil quality was not analyzed    b) Heat exchanger/condenser tubes were not inspected/cleaned at least monthly    c) Compressor high pressure safety cutoffs were not tested at least bi-annually    d) Pressure vessels such as intercoolers and accumulators were not inspected or tested to determine the condition of their wall thickness.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 J04 IV

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 10, 2015
Abate by
Aug 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.119(j)(4)(iv): The employer did not document each inspection and test that was performed on process equipment wherein the documentation identified the date of the inspection or test, the name of the person who performed the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test performed, and the results of the inspection or test.  For the Commercial Warehousing ammonia refrigeration facility located at 101 and 102 Industrial Blvd. in Winter Haven, FL as observed on or about 1/15/2015: preventative maintenance/mechanical integrity inspections of process equipment were not documented. Mechanical integrity inspection/testing documentation for serviced equipment such as, but not limited to, the following were not available:  a) Inspections of piping insulation were not documented.  b) Vibration inspections/analysis of compressors were not documented.  c) Annual testing of compressor float switches, alarms, and cutoffs were not documented.  d) Changing of compressor oil was not documented.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.119 N

Serious Gravity 5 1 instance 62 exposed
Issued
Jul 10, 2015
Abate by
Nov 16, 2015
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.119(n): The employer did not establish an emergency plan for the entire plant in accordance with the provisions of 29 CFR 1910.38:    For the Commercial Warehousing T5/T6 refrigeration system located at 101 and 102 industrial Blvd., Winter Haven, FL as observed between 01/15/2015 and 04/01/2015:     a) The emergency plan was not reviewed with all employees. multiple employees at the facility were not aware of the exit procedures, where the evacuation point was, or who they were supposed to report to in event of an evacuation.    b) There was no alarm system to indicate an ammonia release and fire alarms were only visible/audible on the docks, not in the warehouse freezers/coolers.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.151 C

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 10, 2015
Abate by
Nov 16, 2015
Penalty
Initial $4,500 · Current $3,600 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) For the Commercial Warehousing refrigeration facility at 101 and 102 Industrial Blvd., Winter Haven, as observed on or about 01/15/2015, eyewash/shower stations were not accessible in the work area in that eyewash/shower stations were not located within ammonia refrigeration engine rooms where refrigeration technicians worked.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $4500

1910.119 J04 III

Willful Gravity 10 2 instances 62 exposed
Issued
Jul 10, 2015
Abate by
Mar 15, 2016
Penalty
Initial $63,000 · Current $50,400 Reduced
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience.    For the Commercial Warehousing facility at 101 and 102 Industrial Blvd., Winter Haven, as observed on or about 01/15/2015, piping inspection pressure vessel inspections and tests were not consistent with good engineering practice in that:    a) Refrigerant piping with compromised vapor seal and visibly damaged insulation was not inspected for corrosion damage nor was its insulation repaired. It was observed on site that in engine room T6 North, T5, and for multiple refrigerant piping for evaporators in T5 and T6: insulation was damaged, severe icing was present, and process vessels such as the intercooler in T5 engine room had extensive corrosion present underneath its insulation.    b) Non-destructive testing had not been implemented for insulated ammonia piping and pressure vessels since the process was initiated in 1996-1997. Severe icing was present, melting, icing, and re-melting was observed, insulation was damaged, its vapor barrier removed, and insulation was wet to the touch in that water had absorbed through it. No testing had been done to determine the integrity of the piping of process vessel walls underneath the damaged insulation.
Recent events (2)
  • — I (W) $50400
  • — Z (W) $63000

View Commercial Warehousing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340194489.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.