OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch On Site Restoration, INC. for free Get an email when a new federal OSHA severe-injury report for On Site Restoration, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4601 HILRY HUCKABY III AVENUE
City
SHREVEPORT
State
LA
ZIP
71106
Mailing
8003 ARGEAN LANE, SHREVEPORT, LA 71106
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488210
Employees
4
Ownership type
Private (A)

2 citations on file for this inspection.

1910.107 C03

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 26, 2015
Abate by
Jul 11, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.107(c)(3): Space-heating appliances, steampipes, or hot surfaces shall not be located in a spraying area where deposits of combustible residues may readily accumulate.  On or about January 15, 2015 at 4601 Hilry Huckaby III Ave., Shreveport, LA 71107, the employer allowed the employees to work in a paint spray area while torpedo-style space heaters were being used inside the same spray area in order to keep the area warm.
Recent events (1)
  • · Z (S) $2000

1910.107 D02

Other-than-serious 1 instance 3 exposed
Issued
Jun 26, 2015
Abate by
Jul 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.107(d)(2): 29 CFR 1910.107(d)(2):  Spraying area(s) were not provided with mechanical ventilation adequate to remove flammable vapors, mists or powders to a safe location and to confine and control combustible residues:  On or about January 15, 2015 at 4601 Hilry Huckaby III Ave., Shreveport, LA 71107, the employer allowed employees to spray paint locomotive cars inside a paint spray area without providing mechanical ventilation.