OSHA Inspection: DURAN LOPEZ CONSTRUCTION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DURAN LOPEZ CONSTRUCTION in 720 MICHIGAN AVE, COLUMBUS, OH 43215 (NAICS 238130). OSHA activity number 340197763.

Watch Duran Lopez Construction — free Get an email when a new federal OSHA severe-injury report for Duran Lopez Construction is published. One employer, no account, unsubscribe in one click.
Site address
720 MICHIGAN AVE
City
COLUMBUS
State
OH
ZIP
43215
Mailing
450 EAST COLUMBUS ST., PICKERINGTON, OH 43147
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

5 citations on file for this inspection.

1903.19 D01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $440.00 · Current $440.00
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:  a.  The employer has failed to submit abatement certification and documentation within ten days of the abatement date, February 27, 2015, for a violation of 29 CFR 1926.503(c)(3), issued as citation 1, item 2, and described as follows: Located at the Trotters Gate Apartments Clubhouse, employees were inadequately trained to recognize and identify the hazards of falling and properly utilize conventional fall protection to protect them from a fall hazard.  b.   The employer has failed to submit abatement certification and documentation within ten days of the abatement date, February 27, 2015, for a violation of 29 CFR 1926.1053(b)(1), issued as citation 1, item 3a, and described as follows: Located at the Trotters Gate Apartments Clubhouse, employees were using a 20 foot fiberglass extension ladder that extended approximately 1 foot above the parapet wall to access the roof of the building. Employees were exposed to an approximately 16 foot fall hazard while accessing the roof.  c.  The employer has failed to submit abatement certification and documentation within ten days of the abatement date, February 27, 2015, for a violation of 29 CFR 1926.1053(b)(6), issued as citation 1, item 3b, and described as follows: Located at the Trotters Gate Apartments Clubhouse, employees were using an unsecured 20 foot fiberglass extension ladder that was leaning into the corner of the building to access the roof, exposing employees to a maximum fall hazard of approximately 16 foot.
Recent events (1)
  • — Z (O) $440

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2200.00 · Current $2200.00
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a. Located at the Trotters Gate Apartments Clubhouse, employees were performing sheathing work from the roof of the building without fall protection, exposing employees to a maximum fall hazard of approximately 19 foot.
Recent events (1)
  • — Z (S) $2200

1926.503 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2200.00 · Current $2200.00
29 CFR 1926.503(c): "Retraining." When the employer has reason to believe that any affected employee who has already been trained does not have the understanding and skill required by paragraph (a) of this section, the employer shall retrain each such employee. Circumstances where retraining is required include, but are not limited to, situations where:  29 CFR 1926.503(c)(3): Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill.  a. Located at the Trotters Gate Apartments Clubhouse, employees were inadequately trained to recognize and identify the hazards of falling and properly utilize conventional fall protection to protect them from a fall hazard.
Recent events (1)
  • — Z (S) $2200

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3080.00 · Current $3080.00
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a. Located at the Trotters Gate Apartments Clubhouse, employees were using a 20 foot fiberglass extension ladder that extended approximately 1 foot above the parapet wall to access the roof of the building. Employees were exposed to an approximately 16 foot fall hazard while accessing the roof.
Recent events (1)
  • — Z (S) $3080

1926.1053 B06

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(6): Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.  a. Located at the Trotters Gate Apartments Clubhouse, employees were using an unsecured 20 foot fiberglass extension ladder that was leaning into the corner of the building to access the roof, exposing employees to a maximum fall hazard of approximately 16 foot.
Recent events (1)
  • — Z (S) $0

View DURAN LOPEZ CONSTRUCTION's full OSHA safety record →