OSHA Inspection: ACE PLASTIC, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ACE PLASTIC, INC. in 7942 NORTH 3350 E ROAD, CHATSWORTH, IL 60921 (NAICS 325991). OSHA activity number 340202027.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ACE Plastic, INC. — free Get an email when a new federal OSHA severe-injury report for ACE Plastic, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ACE PLASTIC, INC.
Site address
7942 NORTH 3350 E ROAD
City
CHATSWORTH
State
IL
ZIP
60921
Mailing
7942 NORTH 3350 E ROAD, CHATSWORTH, IL 60921
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325991
Employees
11
Ownership type
A

10 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 20, 2015
Abate by
Aug 31, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    The employer has not established and maintained a continuing, effective hearing conservation program when the following employees exposure to noise exceeds an 8-hour time-weighted average of 85 dBA:      An employee was exposed to continuous noise levels at 80.6% of the permissible daily dose (8-hour time-weighted average sound level of 85 dBA), while performing work activities at the extruder. The equivalent dBA level of the 80.6% is approximately 88.4 dBA. The exposure level is derived from a sample collected over a 324 minute sampling period with zero exposure assumed for the unsampled period of time (156 minutes).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.95 I02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 20, 2015
Abate by
Apr 30, 2015
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(i)(2)(ii): The employer did not ensure that hearing protectors are worn by any employee who is exposed to an 8-hour time-weighted average of 85 decibels or greater:   Employees were exposed to continuous noise over an 8-hour time weighted average sound level of 85 decibels and the employer did not ensure that hearing protectors were worn.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 8 exposed
Issued
Apr 20, 2015
Abate by
Jul 30, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    Employees conducted service and maintenance on an extruder, shredder, and grinding machines and the employer did not establish energy control procedures for each machine.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.178 L01 I

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 20, 2015
Abate by
Aug 31, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):      The employer did not ensure that each operator had completed training that included all of the truck and workplace related topics listed in the standard and completed an evaluation of the operators performance through practical exercises.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.219 F03

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 20, 2015
Abate by
Apr 30, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:    Employees in the grinding area were exposed to caught-in hazards and the unguarded chain and sprocket on the belt conveyor was not enclosed.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 20, 2015
Abate by
Apr 30, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Employees working in the grinding area were exposed to electrical shock due to electrical equipment not installed in accordance with the listing or labeling:    a.    Junction box on the Weima shredder was not secured to prevent movement;    b.    Snap switch on a panel board was not installed in accordance with listing or labeling.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.305 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 20, 2015
Abate by
Apr 30, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:    Employees operating Grinder #1 were exposed to electrical shock due to the control panel having conductors entering the box and the fittings were not effectively closed.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.305 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 20, 2015
Abate by
Apr 30, 2015
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    Employees operating the Weima shredder were exposed to electrical shock due to a junction box with a missing cover.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1600

1910.141 D01

Other-than-serious 1 instance 2 exposed
Issued
Apr 20, 2015
Abate by
May 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(1): Washing facilities were not maintained in a sanitary condition:  The men's restroom facilities in the plant were not maintained in a sanitary condition.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.141 D02 IV

Other-than-serious 1 instance 8 exposed
Issued
Apr 20, 2015
Abate by
May 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(iv): Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling:    The men's restroom facilities in the plant were not provided with hand towels.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ACE Plastic, INC.'s full OSHA safety record →