PHOENIX, AZ —
OSHA Inspection: ARIZONA AIR NATIONAL GUARD
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ARIZONA AIR NATIONAL GUARD in 3200 E. OLD TOWER ROAD MAINTENANCE GROUP, PHOENIX, AZ 85034 (NAICS 561210). OSHA activity number 340202563.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARIZONA AIR NATIONAL GUARD
- Site address
- 3200 E. OLD TOWER ROAD MAINTENANCE GROUP
- City
- PHOENIX
- State
- AZ
- ZIP
- 85034
- Mailing
- 3200 E. OLD TOWER ROAD GROUND SAFETY, PHOENIX, AZ 85034
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561210
- Employees
- 66
- Ownership type
- D
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Feb 24, 2015
- Abate by
- Apr 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Maintenance Fabrication Shop: On or about January 23, 2015 and at times prior thereto, the rotating parts of the following machines were not guarded: a) Bridgeport Mill Machine (1G113) b) Delta Model 20 Drill Press c) Drill Press (1G111) d) DoAll Band Saw (1G101) e) Bradford Lathe f) DoAll Band Saw (1G102) g) Clausing Model 2221 Drill Press
Recent events (1)
- — Z (S) $0
1910.303 B02
- Issued
- Feb 24, 2015
- Abate by
- Mar 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Break Room, Nondestructive Inspection (NDI) Shop: On or about January 23, 2015 and at times prior thereto, a relocatable power tap was used to power high current draw appliances such as a broiler oven and coffee maker.
Recent events (1)
- — Z (S) $0
More inspections at Arizona AIR National Guard
View Arizona AIR National Guard's full OSHA safety record →
More inspections in this industry (NAICS 561210)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340202563.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.