Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COAL AUGER PRO

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COAL AUGER PRO in 301 INDUSTRIAL DRIVE, CARROLLTON, OH 44615 (NAICS 333131). OSHA activity number 340202654.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coal Auger PRO — free Get an email when a new federal OSHA severe-injury report for Coal Auger PRO is published. One employer, no account, unsubscribe in one click.
Establishment
COAL AUGER PRO
Site address
301 INDUSTRIAL DRIVE
City
CARROLLTON
State
OH
ZIP
44615
Mailing
2234 ROSWELL ROAD, S.W., CARROLLTON, OH 44615
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333131
Employees
7
Ownership type
A

2 citations on file for this inspection.

1910.305 B01 II

Serious Gravity 1 2 instances 7 exposed
Issued
Apr 7, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.  a.  On or about January 23, 2015, located in the fabrication shop behind the horizontal band saw, there was a 177 volt electrical panel box that was used in part to supply electrical power to the shop's overhead lights which had knockouts that were not effectively closed, thereby exposing the employees to a burn injury if an arc flash would occur.    b.  On or about January 23, 2015, located in the fabrication shop behind the horizontal band saw, there was a 120 volt electrical panel box that was used in part to supply electrical power to the shop's receptacle outlets which had knockouts that were not effectively closed, thereby exposing the employees to a burn injury if an arc flash would occur.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1910.179 G01 IV

Other-than-serious 1 instance 7 exposed
Issued
Apr 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.179(g)(1)(iv): Where multiple conductor cable is used with a suspended pushbutton station, the station must be supported in some satisfactory manner that will protect the electrical conductors against strain.  a.  On or about January 23, 2015, located in the East Bay on the 10 ton overhead crane, the employer did not ensure that a pendant control box (suspended pushbutton station) had strain relief provided at the point where the multiple conductor cable connected to the pendant control box.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340202654.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.