Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STRATTON EQUITY COOP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STRATTON EQUITY COOP in 1750 RAILROAD AVE, BURLINGTON, CO 80807 (NAICS 493130). OSHA activity number 340205129.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stratton Equity Coop — free Get an email when a new federal OSHA severe-injury report for Stratton Equity Coop is published. One employer, no account, unsubscribe in one click.
Site address
1750 RAILROAD AVE
City
BURLINGTON
State
CO
ZIP
80807
Mailing
P.O. BOX 25, STRATTON, CO 80836
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493130
Employees
7
Ownership type
A

6 citations on file for this inspection.

1910.23 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 10, 2015
Abate by
Apr 24, 2015
Penalty
Initial $4,208 · Current $2,104 Reduced
29 CFR 1910.23(a)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v):    (a)  On or about January 20, 2015, and at times prior, the employer did not ensure that employees were protected from fall and struck-by hazards in the personnel lift shaft in the east elevator building in that the back side of the which was unguarded at each level of the elevator.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2104
  • — Z (S) $4208

1910.23 A02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 10, 2015
Abate by
Apr 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening:  (a)  On or about January 20, 2015, and at times prior, the employer did not ensure that employees were protected from falls from the rest platforms of the access ladders that lead to the top of the steel grain bins which employees climb to inspect and maintain the machinery on top and to inspect and measure the grain inside.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 J01

Serious Gravity 5 2 instances 7 exposed
Issued
Mar 10, 2015
Abate by
Apr 24, 2015
Penalty
Initial $4,208 · Current $2,104 Reduced
29 CFR 1910.272(j)(1): The employer did not develop and implement a written housekeeping program that established the frequency and the method(s) determined best to reduce accumulations of fugitive grain dust on ledges, floors, equipment, and other exposed surfaces:    (a)  On or about January 20, 2015, and at times prior, the employer did not ensure that employees were protected from grain dust explosions by removing fugitive grain dust from all exposed surfaces in the following locations:  1) The tunnel of the east building in the dust collection system that is no longer in use and runs adjacent to the conveyor belt.  2) The west building:      (i)   bin deck of the west building on the horizontal surfaces along of the distributor legs.      (ii)  in a rectangular box stored in the northwest area of the bin deck adjacent from the distributor legs.      (iii) on many pieces of angle iron attached at to the cement wall up the shaft of the personnel lift.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2104
  • — Z (S) $4208

1910.272 O01

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 10, 2015
Abate by
May 24, 2015
Penalty
Initial $4,208 · Current $2,104 Reduced
29 CFR 1910.272(o)(1): The employer did not provide at least two means of emergency escape from galleries (bin decks) in the grain handling facility:    (a)  On or about January 20, 2015, and at times prior, the employer did not ensure that employees accessing the headhouse of the east elevator had more that one exit route in case of an emergency.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2104
  • — Z (S) $4208

1910.147 F03

Other-than-serious 1 instance 5 exposed
Issued
Mar 10, 2015
Abate by
Apr 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3): 29 CFR 1910.147(f)(3): When servicing and/or maintenance was performed by a crew, craft, department or other group,  the employer did not ensure that employee(s) utilized a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device:  (a)  On or about January 20, 2015, and at times prior, the employer did not ensure that employees using a group lockout system were all protected from hazardous energy in that the steps for administering and removing group lockout devices was not defined in the facility's Lockout/Tag Out plan.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 II

Other-than-serious 1 instance 5 exposed
Issued
Mar 10, 2015
Abate by
Apr 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  (a)  On or about January 20, 2015, and at times prior, the employer did not ensure that the energy control inspections for the folloing procedures were performed annually:   1)  Truck Probe   2)  Leg, West Elevator   3)  Manlift, East Elevator   4)  Steel Bin Drag and Augers   5)  Fans, East Elevator   6)  Top Belt, East Elevator   7)  Top Drag, East Elevator   8)  Dust Bin, East Elevator   9)  Dust Bin, West Elevator   10)  Manlift, West Elevator   11)  Top Belt, West Elevator   12)  Steel Bin Drags and Augers, West Elevator   13)  Fans, West Elevator   14)  Truck Probe, West Elevator  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Stratton Equity Coop's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340205129.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.