WESTONS MILLS, NY —
OSHA Inspection: KEYSTONE TOOL & DIE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KEYSTONE TOOL & DIE, INC. in 1410 OLEAN - PORTVILLE RD., WESTONS MILLS, NY 14788 (NAICS 333515). OSHA activity number 340205871.
Where did this inspection happen?
- Establishment
- KEYSTONE TOOL & DIE, INC.
- Site address
- 1410 OLEAN - PORTVILLE RD.
- City
- WESTONS MILLS
- State
- NY
- ZIP
- 14788
- Mailing
- P.O. BOX 604, WESTONS MILLS, NY 14788
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333515
- Employees
- 65
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2400.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed and documented for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 01/28/2015 throughout establishment; where employees perform servicing and maintenance on machines and equipment such as, but not limited to: changing saw blades, shear blades and v-belts, the employer did not develop and document procedures for controlling hazardous energy. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2400
- — Z (S) $3500
1910.147 C06 I C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 01/28/2015 throughout establishment; where employees routinely perform servicing and maintenance on machines and equipment utilizing locks for energy control. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $2400.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about 01/28/2015 in the production area; where employees use "Val Pro Purple Magic", a corrosive chemical, pumped out of a 55 gallon drum for cleaning and degreasing. There was no eye wash or emergency shower in the area. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2400
- — Z (S) $3500
1910.157 G01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: a) On or about 01/28/2015 throughout establishment; where the employer has provided portable fire extinguishers and allows/permits all employees to use the fire extinguishers to fight incipient stage fires. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) On or about 01/28/2015 throughout establishment; where the employees operate powered industrial vehicles to move parts and equipment throughout the facility. The last training/evaluation was more than ten years ago. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.157 E02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: a) On or about 01/28/2015 throughout establishment; where the employer has provided portable fire extinguishers throughout the establishment for employee use to fight incipient stage fires. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.184 C07
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(c)(7): Sling(s) were not padded or protected from sharp edges of their loads: a) On or about 01/28/2014 in the assembly area; where a fabricated steel ring (approximately 10 feet in diameter, weighing approximately 12,000 pounds) was being lifted using 3 synthetic web slings which were not padded to protect against the sharp corner of the steel. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333515)
KINGSFORD, MI—2026-07-14
KINGSFORD BROACH & TOOL INC
WEAVERVILLE, NC—2026-06-05
161309 - HYDE TOOLS, INC.
SOLON, OH—2026-05-18
KENNAMETAL
SOLON, OH—2026-05-13
KENNAMETAL INC.
CADILLAC, MI—2026-04-20
DUMBARTON TOOL, INC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16